3D-Mesa 'Bridge' Silicon Microdosimeter: Charge Collection Study and Application to RBE Studies in $^{12}{\rm C}$ Radiation Therapy
العنوان: | 3D-Mesa 'Bridge' Silicon Microdosimeter: Charge Collection Study and Application to RBE Studies in $^{12}{\rm C}$ Radiation Therapy |
---|---|
المؤلفون: | Vladimir Perevertaylo, Lachlan Chartier, Michael L. F Lerch, Susanna Guatelli, Dale A. Prokopovich, Anatoly B. Rosenfeld, Marco Petasecca, Marco Zaider, Linh T. Tran, Mark I. Reinhard, Michael Jackson, Mitchell Nancarrow, Naruhiro Matsufuji |
المصدر: | IEEE Transactions on Nuclear Science. 62:504-511 |
بيانات النشر: | Institute of Electrical and Electronics Engineers (IEEE), 2015. |
سنة النشر: | 2015 |
مصطلحات موضوعية: | Physics, Nuclear and High Energy Physics, Microprobe, medicine.medical_specialty, Silicon, Proportional counter, chemistry.chemical_element, Radiation, Ion, Nuclear physics, Nuclear Energy and Engineering, chemistry, medicine, Relative biological effectiveness, Dosimetry, Medical physics, Electrical and Electronic Engineering, Beam (structure) |
الوصف: | Microdosimetry is an extremely useful technique, used for dosimetry in unknown mixed radiation fields typical of space and aviation, as well as in hadron therapy. A new silicon microdosimeter with 3D sensitive volumes has been proposed to overcome the shortcomings of the conventional Tissue Equivalent Proportional Counter. In this article, the charge collection characteristics of a new 3D mesa microdosimeter were investigated using the ANSTO heavy ion microprobe utilizing 5.5 MeV ${\rm He}^{2 +}$ and 2 MeV ${\rm H}^ {+}$ ions. Measurement of the microdosimetric characteristics allowed for the determination of the Relative Biological Effectiveness of the $^{12}{\rm C}$ heavy ion therapy beam at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Well-defined sensitive volumes of the 3D mesa microdosimeter have been observed and the microdosimetric RBE obtained showed good agreement with the TEPC. The new 3D mesa “bridge” microdosimeter is a step forward towards a microdosimeter with fully free-standing 3D sensitive volumes. |
تدمد: | 1558-1578 0018-9499 |
DOI: | 10.1109/tns.2015.2391102 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_________::7faa4c811eeca6eb1c480405aa751a04 https://doi.org/10.1109/tns.2015.2391102 |
Rights: | CLOSED |
رقم الانضمام: | edsair.doi...........7faa4c811eeca6eb1c480405aa751a04 |
قاعدة البيانات: | OpenAIRE |
تدمد: | 15581578 00189499 |
---|---|
DOI: | 10.1109/tns.2015.2391102 |