Response functions of multi-pixel-type CdTe detector: toward development of precise material identification on diagnostic x-ray images by means of photon counting

التفاصيل البيبلوغرافية
العنوان: Response functions of multi-pixel-type CdTe detector: toward development of precise material identification on diagnostic x-ray images by means of photon counting
المؤلفون: Masahiro Okada, Tsutomu Yamakawa, Shuichiro Yamamoto, Yuki Kanazawa, Natsumi Kimoto, Hiroaki Hayashi, Takashi Asahara, Masashi Yamasaki
المصدر: Medical Imaging 2017: Physics of Medical Imaging.
بيانات النشر: SPIE, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Physics, Photon, Pixel, business.industry, Scattering, Detector, 010403 inorganic & nuclear chemistry, 01 natural sciences, Photon counting, Spectral line, 030218 nuclear medicine & medical imaging, 0104 chemical sciences, Charge sharing, 03 medical and health sciences, 0302 clinical medicine, Optics, Calibration, business
الوصف: Currently, an X-ray imaging system which can produced information used to identify various materials has been developed based on photon counting. It is important to estimate the response function of the detector in order to accomplish highly accurate material identification. Our aim is to simulate the response function of a CdTe detector using Monte-Carlo simulation; at this time, the transportation of incident and scattered photons and secondary produced electrons were precisely simulated without taking into consideration the charge spread in the collecting process of the produced charges (charge sharing effect). First, we set pixel sizes of 50-500μm, the minimum irradiation fields which produce equilibrium conditions were determined. Then, observed peaks in the response function were analyzed with consideration paid to the interactions between incident X-rays and the detector components, Cd and Te. The secondary produced characteristic X-rays play an important role. Accordingly ratios of full energy peak (FEP), scattering X-rays and penetrating X-rays in the calculated response functions were analyzed. When the pixel size of 200μm was used the scattered X-rays were saturated at equilibrium with relatively small fields and efficiency of FEP was kept at a high value (
تدمد: 0277-786X
DOI: 10.1117/12.2251185
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::4fd10df79680ccbe661d539d620a3297
https://doi.org/10.1117/12.2251185
رقم الانضمام: edsair.doi...........4fd10df79680ccbe661d539d620a3297
قاعدة البيانات: OpenAIRE
الوصف
تدمد:0277786X
DOI:10.1117/12.2251185