Biomechanical Performance of 2 Sutures Used in Flexor Tendon Repair
العنوان: | Biomechanical Performance of 2 Sutures Used in Flexor Tendon Repair |
---|---|
المؤلفون: | Vilmos Vécsei, M. Bijak, E. Unger, G. Vekszler, J. T. Hausmann, M. Schurz |
المصدر: | Osteosynthesis and Trauma Care. 15:80-83 |
بيانات النشر: | Georg Thieme Verlag KG, 2007. |
سنة النشر: | 2007 |
مصطلحات موضوعية: | Orthodontics, Ultimate load, Flexor tendon repair, Suture (anatomy), Flexor tendon, business.industry, Medicine, Anatomy, musculoskeletal system, Biomechanical testing, business, Breaking strength, Tensile testing |
الوصف: | We performed a biomechanical study comparing two sutures (Ticron; Ethibond Exel) commonly used in flexor tendon surgery. With the use of a custom-made tensile tester ultimate load to failure testing with and without cyclic preloading was performed. The median breaking strength of the Ticron suture was 28 N without and 27.4 N with cyclic preloading, for the Ethibond Exel suture 33 N without and 34 N with cyclic preloading. The mean elongation after cyclic preloading was 3.3 mm for the Ticron suture and 4.5 mm for the Ethibond Exel suture, respectively. On the basis of these data, recommendations are made on the use of the Ethibond Exel suture for flexor tendon surgery. |
تدمد: | 1618-9728 1618-971X |
DOI: | 10.1055/s-2007-960708 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_________::422cad4b20abcf0b90007267ce889441 https://doi.org/10.1055/s-2007-960708 |
رقم الانضمام: | edsair.doi...........422cad4b20abcf0b90007267ce889441 |
قاعدة البيانات: | OpenAIRE |
تدمد: | 16189728 1618971X |
---|---|
DOI: | 10.1055/s-2007-960708 |