Shock timing technique for the National Ignition Facility

التفاصيل البيبلوغرافية
العنوان: Shock timing technique for the National Ignition Facility
المؤلفون: David H. Munro, Bruce Hammel, S. W. Haan, P. M. Celliers, Luiz B. Da Silva, R. C. Cauble, W. W. Hsing, D. M. Gold, Gilbert Collins
المصدر: Physics of Plasmas. 8:2245-2250
بيانات النشر: AIP Publishing, 2001.
سنة النشر: 2001
مصطلحات موضوعية: Physics, Shock wave, business.industry, Nova (laser), Condensed Matter Physics, Laser, Shock (mechanics), law.invention, Ignition system, Interferometry, Optics, law, business, National Ignition Facility, Inertial confinement fusion
الوصف: Among the final shots at the Nova laser [Campbell et al., Rev. Sci. Instrum. 57, 2101 (1986)] was a series testing the VISAR (velocity interferometry system for any reflector) technique that will be the primary diagnostic for timing the shocks in a NIF (National Ignition Facility) ignition capsule. At Nova, the VISAR technique worked over the range of shock strengths and with the precision required for the NIF shock timing job—shock velocities in liquid D2 from 12 to 65 μm/ns with better than 2% accuracy. VISAR images showed stronger shocks overtaking weaker ones, which is the basis of the plan for setting the pulse shape for the NIF ignition campaign. The technique is so precise that VISAR measurements may also play a role in certifying beam-to-beam and shot-to-shot repeatability of NIF laser pulses.
تدمد: 1089-7674
1070-664X
DOI: 10.1063/1.1347037
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::172a831abe30481489602e560596e2e2
https://doi.org/10.1063/1.1347037
رقم الانضمام: edsair.doi...........172a831abe30481489602e560596e2e2
قاعدة البيانات: OpenAIRE
الوصف
تدمد:10897674
1070664X