Methods to Minimize Optical Noise That Degrade Fluorescence Efficiency of Optical Probe for Near-Infrared Tracking in Surgical Environment

التفاصيل البيبلوغرافية
العنوان: Methods to Minimize Optical Noise That Degrade Fluorescence Efficiency of Optical Probe for Near-Infrared Tracking in Surgical Environment
المؤلفون: Seok-Ki Kim, Jae Seok Park, In Hee Shin, Joo Beom Eom, Byeong-Il Lee, Hyeong Ju Park
المصدر: Journal of Biomedical Science and Engineering. :56-65
بيانات النشر: Scientific Research Publishing, Inc., 2015.
سنة النشر: 2015
مصطلحات موضوعية: Materials science, business.industry, Near-infrared spectroscopy, Filter (signal processing), Signal, Fluorescence, law.invention, Wavelength, Optics, law, Image noise, Optoelectronics, Darkroom, business, Light-emitting diode
الوصف: In the medical field, there are growing interests in applied research such as in vivo fluorescence monitoring because of excellent body transmission characteristic of the near-infrared light. However, optical noise by excitation light and illumination equipment for medical applications such as interior light, surgical light decrease efficiency of the fluorescent signal when observers such as surgeons confirm fluorescence signals in medical field. To solve these problems in medical field, we have analyzed external noise factors by effect on image realization, quantification of optical noise generation by external factors, and have suggested methods of minimize the optical noise in this paper. In case of fluorescence imaging in the operating room, it has been confirmed that fluorescent excitation light, interior light and surgical light are factors to generate optical noise. To acquire near-infrared fluorescence images and to compare fluorescence contrast under conditions of darkroom, interior light and surgical light, light emitting diodes (LEDs) sources that have peak wavelength at 740, 760 and 780 nm respectively were used as excitation light sources. In addition, short-pass filter which has transmission edge at 775 nm has been applied to minimize the optical noise in each external noise factor. By comparing contrast of each image before and after use of the short-pass filter, we confirmed that optical noise reduced 49%, 56% and 66% in external noise factors respectively.
تدمد: 1937-688X
1937-6871
DOI: 10.4236/jbise.2015.81006
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::11c41662e7cfe022d76d22d1a382b4ef
https://doi.org/10.4236/jbise.2015.81006
Rights: OPEN
رقم الانضمام: edsair.doi...........11c41662e7cfe022d76d22d1a382b4ef
قاعدة البيانات: OpenAIRE
الوصف
تدمد:1937688X
19376871
DOI:10.4236/jbise.2015.81006