Efficacy of 3 Commonly Used Hearing Aid CircuitsA Crossover Trial

التفاصيل البيبلوغرافية
العنوان: Efficacy of 3 Commonly Used Hearing Aid CircuitsA Crossover Trial
المؤلفون: Richard H. Wilson, Gerald A. Studebaker, Vernon D. Larson, B. Z. Rappaport, Allen E. Boysen, Patricia G. Stelmachowicz, Lucille B. Beck, William G. Henderson, Lynn E. Luethke, David W. Williams, Amy M. Donahue, Stephen A. Fausti, George B. Haskell, Rinaldo F. Canalis, Janet E. Shanks, Douglas Noffsinger, Gene W. Bratt, Robert A. Dobie
المصدر: JAMA. 284:1806
بيانات النشر: American Medical Association (AMA), 2000.
سنة النشر: 2000
مصطلحات موضوعية: Hearing aid, medicine.medical_specialty, business.industry, Hearing loss, medicine.medical_treatment, General Medicine, Audiology, medicine.disease, Crossover study, Loudness, otorhinolaryngologic diseases, Medicine, Active listening, Sensorineural hearing loss, Sound quality, medicine.symptom, business, Veterans Affairs
الوصف: ContextNumerous studies have demonstrated that hearing aids provide significant benefit for a wide range of sensorineural hearing loss, but no carefully controlled, multicenter clinical trials comparing hearing aid efficacy have been conducted.ObjectiveTo compare the benefits provided to patients with sensorineural hearing loss by 3 commonly used hearing aid circuits.DesignDouble-blind, 3-period, 3-treatment crossover trial conducted from May 1996 to February 1998.SettingEight audiology laboratories at Department of Veterans Affairs medical centers across the United States.PatientsA sample of 360 patients with bilateral sensorineural hearing loss (mean age, 67.2 years; 57% male; 78.6% white).InterventionPatients were randomly assigned to 1 of 6 sequences of linear peak clipper (PC), compression limiter (CL), and wide dynamic range compressor (WDRC) hearing aid circuits. All patients wore each of the 3 hearing aids, which were installed in identical casements, for 3 months.Main Outcome MeasuresResults of tests of speech recognition, sound quality, and subjective hearing aid benefit, administered at baseline and after each 3-month intervention with and without a hearing aid. At the end of the experiment, patients ranked the 3 hearing aid circuits.ResultsEach circuit markedly improved speech recognition, with greater improvement observed for soft and conversationally loud speech (all 52-dB and 62-dB conditions, P≤.001). All 3 circuits significantly reduced the frequency of problems encountered in verbal communication. Some test results suggested that CL and WDRC circuits provided a significantly better listening experience than PC circuits in word recognition (P = .002), loudness (P = .003), overall liking (P = .001), aversiveness of environmental sounds (P = .02), and distortion (P = .02). In the rank-order ratings, patients preferred the CL hearing aid circuits more frequently (41.6%) than the WDRC (29.8%) and the PC (28.6%) (P = .001 for CL vs both WDRC and PC).ConclusionsEach circuit provided significant benefit in quiet and noisy listening situations. The CL and WDRC circuits appeared to provide superior benefits compared with the PC, although the differences between them were much less than the differences between the aided vs unaided conditions.
تدمد: 0098-7484
DOI: 10.1001/jama.284.14.1806
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::0349f58be33c2b7d8d6b165e4d17889b
https://doi.org/10.1001/jama.284.14.1806
رقم الانضمام: edsair.doi...........0349f58be33c2b7d8d6b165e4d17889b
قاعدة البيانات: OpenAIRE
الوصف
تدمد:00987484
DOI:10.1001/jama.284.14.1806