Error-corrected Duplex Sequencing enables direct detection and quantification of mutations in human TK6 cells with remarkable inter-laboratory consistency

التفاصيل البيبلوغرافية
العنوان: Error-corrected Duplex Sequencing enables direct detection and quantification of mutations in human TK6 cells with remarkable inter-laboratory consistency
المؤلفون: Eunnara Cho, Carol D. Swartz, Andrew Williams, Miriam Rivas, Leslie Recio, Kristine L. Witt, Elizabeth K. Schmidt, Jeffry Yaplee, Thomas H. Smith, Phu Van, Fang Yin Lo, Charles C. Valentine, Jesse J. Salk, Francesco Marchetti, Stephanie L. Smith-Roe, Carole L. Yauk
بيانات النشر: Cold Spring Harbor Laboratory, 2023.
سنة النشر: 2023
الوصف: Error-corrected Duplex Sequencing (DuplexSeq) enables direct quantification of low-frequency mutations and offers tremendous potential for chemical mutagenicity assessment. We investigated the utility of DuplexSeq to quantify induced mutation frequency (MF) and spectrum in human lymphoblastoid TK6 cells exposed to a prototypical DNA alkylating agent,N-ethyl-N-nitrosourea (ENU). Furthermore, we explored appropriate experimental parameters for this application, and assessed inter-laboratory reproducibility. In two independent experiments in two laboratories, TK6 cells were exposed to ENU (25-200 µM) and DNA was sequenced 48, 72, and 96 h post-exposure. A DuplexSeq mutagenicity panel targeting twenty 2.4-kb regions distributed across the genome was used to sample diverse, genome-representative sequence contexts. A robust increase in MF that was unaffected by time was observed in both laboratories. Concentration-response in the MF from the two laboratories was strongly positively correlated (R2=0.95). C:G>T:A, T:A>C:G, T:A>A:T, and T:A>G:C mutations increased in consistent, concentration-dependent manners in both laboratories, with high proportions of C:G>T:A at all time points. The target sites responded similarly between the two laboratories and revealed a higher average MF in intergenic regions. These results, demonstrating remarkable reproducibility across time and laboratory for both MF and spectrum, support the high value of DuplexSeq for characterizing chemical mutagenicity in both research and regulatory evaluation.
DOI: 10.1101/2023.02.22.529418
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_________::0297e7108e98c4ad7df2f12bf5adc5ad
https://doi.org/10.1101/2023.02.22.529418
رقم الانضمام: edsair.doi...........0297e7108e98c4ad7df2f12bf5adc5ad
قاعدة البيانات: OpenAIRE
الوصف
DOI:10.1101/2023.02.22.529418