Academic Journal

Influence of Multi Stenosis on Hemodynamic Parameters in an Idealized Coronary Artery Model.

التفاصيل البيبلوغرافية
العنوان: Influence of Multi Stenosis on Hemodynamic Parameters in an Idealized Coronary Artery Model.
المؤلفون: Kamangar, S.
المصدر: Journal of Applied Fluid Mechanics; Jan/Feb2022, Vol. 15 Issue 1, p15-23, 9p
مصطلحات موضوعية: CORONARY arteries, HEMODYNAMICS, STENOSIS, SHEARING force, SHEAR walls, COMPUTATIONAL fluid dynamics
مستخلص: This study explores the influence of tandem stenosis on hemodynamic constraints in idealized coronary artery models with different interspace distance between the stenosis and its severity. The blood was assumed as non- Newtonian, incompressible, and pulsatile fluid. The hemodynamic parameters of blood, such as the oscillatory shear index (OSI), wall shear stress (WSS) and time average wall shear stress (TAWSS) are obtained and compared for various degrees of stenosis and interspacing distance in various blood models. The computed results showed that as the interspacing distance between the stenosis decreases, the low wall shear stress area increases for the model P70_D70, leading to further progression of stenosis in the distal region. No significant variation was observed for the model P70_D90, whereas the low WSS region increases as the interspace distance of proximal and distal stenosis increases for the model P90_D70. The highest TAWSS sites were created across the 90% AS (area stenosis) for all the cases studied. As the higher value of TAWSS is clinically significant since it could damage the endothelial layer. It is well known that the maximum value of OSI is strongly associated with the critical areas of stenosis rupture. The maximum value of OSI was found at the proximal and distal stenosis for all the models simulated. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Applied Fluid Mechanics is the property of Isfahan University of Technology, Faculty of Agricultural Engineering and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:17353572
DOI:10.47176/jafm.15.01.32597