Effects of incorrect computer-aided detection (CAD) output on human decision-making in mammography.

التفاصيل البيبلوغرافية
العنوان: Effects of incorrect computer-aided detection (CAD) output on human decision-making in mammography.
المؤلفون: Alberdi, Eugenio, Povyakalo, Andrey, Strigini, Lorenzo, Ayton, Peter, Povykalo, Andrey
المصدر: Academic Radiology; Aug2004, Vol. 11 Issue 8, p909-918, 10p
مصطلحات موضوعية: COMPUTER-aided design, COMPUTER-aided engineering, MAMMOGRAMS, BREAST exams
مستخلص: Rationale and Objectives: To investigate the effects of incorrect computer output on the reliability of the decisions of human users. This work followed an independent UK clinical trial that evaluated the impact of computer-aided detection(CAD) in breast screening. The aim was to use data from this trial to feed into probabilistic models (similar to those used in "reliability engineering") which would detect and assess possible ways of improving the human-CAD interaction. Some analyses required extra data; therefore, two supplementary studies were conducted. Study 1 was designed to elucidate the effects of computer failure on human performance. Study 2 was conducted to clarify unexpected findings from Study 1.Materials and Methods: In Study 1, 20 film readers viewed 60 sets of mammograms (30 of which contained cancer) and provided "recall/no recall" decisions for each case. Computer output for each case was available to the participants. The test set was designed to contain an unusually large proportion (50%) of cancers for which CAD had generated incorrect output. In Study 2, 19 different readers viewed the same set of cases in similar conditions except that computer output was not available.Results: The average sensitivity of readers in Study 1 (with CAD) was significantly lower than the average sensitivity of read-ers in Study 2 (without CAD). The difference was most marked for cancers for which CAD failed to provide correct prompting.Conclusion: Possible automation bias effects in CAD use deserve further study because they may degrade human decision-making for some categories of cases under certain conditions. This possibility should be taken into account in the assessment and design of CAD tools. [ABSTRACT FROM AUTHOR]
Copyright of Academic Radiology is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:10766332
DOI:10.1016/j.acra.2004.05.012