التفاصيل البيبلوغرافية
العنوان: |
Segmenting time-lapse phase contrast images of adjacent NIH 3T3 cells. |
المؤلفون: |
CHALFOUN, J., KOCIOLEK, M., DIMA, A., HALTER, M., CARDONE, A., PESKIN, A., BAJCSY, P., BRADY, M. |
المصدر: |
Journal of Microscopy; Jan2013, Vol. 249 Issue 1, p41-52, 12p |
مصطلحات موضوعية: |
CHRONOPHOTOGRAPHY, IMAGE segmentation, AUTOMATION, FLOW cytometry, CYTOLOGY, PIXELS, COMPARATIVE studies |
مستخلص: |
We present a new method for segmenting phase contrast images of NIH 3T3 fibroblast cells that is accurate even when cells are physically in contact with each other. The problem of segmentation, when cells are in contact, poses a challenge to the accurate automation of cell counting, tracking and lineage modelling in cell biology. The segmentation method presented in this paper consists of (1) background reconstruction to obtain noise-free foreground pixels and (2) incorporation of biological insight about dividing and nondividing cells into the segmentation process to achieve reliable separation of foreground pixels defined as pixels associated with individual cells. The segmentation results for a time-lapse image stack were compared against 238 manually segmented images (8219 cells) provided by experts, which we consider as reference data. We chose two metrics to measure the accuracy of segmentation: the 'Adjusted Rand Index' which compares similarities at a pixel level between masks resulting from manual and automated segmentation, and the 'Number of Cells per Field' (NCF) which compares the number of cells identified in the field by manual versus automated analysis. Our results show that the automated segmentation compared to manual segmentation has an average adjusted rand index of 0.96 (1 being a perfect match), with a standard deviation of 0.03, and an average difference of the two numbers of cells per field equal to 5.39% with a standard deviation of 4.6%. [ABSTRACT FROM AUTHOR] |
|
Copyright of Journal of Microscopy is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
قاعدة البيانات: |
Complementary Index |