Academic Journal

Droplet Digital PCR Enhances Sensitivity of Canine Distemper Virus Detection.

التفاصيل البيبلوغرافية
العنوان: Droplet Digital PCR Enhances Sensitivity of Canine Distemper Virus Detection.
المؤلفون: Iribarnegaray, Victoria, Godiño, Guillermo, Larrañaga, Camila, Yamasaki, Kanji, Verdes, José Manuel, Puentes, Rodrigo
المصدر: Viruses (1999-4915); Nov2024, Vol. 16 Issue 11, p1720, 14p
مصطلحات موضوعية: CANINE distemper virus, MOLECULAR diagnosis, DETECTION limit, SYMPTOMS, VETERINARIANS
مستخلص: Canine distemper virus (CDV) poses a substantial threat to diverse carnivorans, leading to systemic and often fatal diseases. Accurate and prompt diagnosis is paramount for effective management and curbing further transmission. This study evaluates the diagnostic performance of droplet digital PCR (ddPCR) in comparison to conventional reverse-transcription (RT-PCR) and quantitative reverse-transcription real-time PCR (RT-qPCR). Seventy-six clinical samples were collected from dogs with CDV symptoms diagnosed by specialized veterinarians, and sixteen samples from apparently healthy individuals. Conventional PCR, quantitative real-time PCR, and ddPCR were deployed, and their diagnostic capabilities were meticulously assessed. DdPCR exhibited heightened analytical sensitivity, reaching a detection limit of 3 copies/μL, whereas RT-qPCR had a detection limit of 86 copies/μL. The comparative analysis between clinical diagnosis and molecular techniques, including RT-PCR and RT-qPCR, demonstrated low concordance, with Kappa coefficients of 0.268 and 0.324, respectively. In contrast, ddPCR showed a moderate concordance, with a Kappa coefficient of 0.477. The sensitivity was 42.4% for RT-PCR, 57.9% for RT-qPCR, and 72.4% for ddPCR, with 100% specificity for all methods. This study underscores ddPCR's superior sensitivity and agreement with clinical CDV diagnosis, even at low viral concentrations, suggesting it as a promising alternative for CDV diagnosis. [ABSTRACT FROM AUTHOR]
Copyright of Viruses (1999-4915) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:19994915
DOI:10.3390/v16111720