Academic Journal

Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map.

التفاصيل البيبلوغرافية
العنوان: Reducing the Cooling Energy Demand by Optimizing the Airflow Distribution in a Ventilated Roof: Numerical Study for an Existing Residential Building and Applicability Map.
المؤلفون: Rincón-Casado, Alejandro, Rodríguez Jara, Enrique Ángel, Ruiz Pardo, Alvaro, Salmerón Lissén, José Manuel, Sánchez de la Flor, Francisco José
المصدر: Applied Sciences (2076-3417); Aug2024, Vol. 14 Issue 15, p6596, 18p
مصطلحات موضوعية: CONSTRUCTION slabs, RETROFITTING of buildings, THERMAL efficiency, SEQUENTIAL analysis, HEAT flux
مستخلص: This work presents a study of a ventilated hollow core slab system (VHCS) that obviates the need to completely replace the slab of an existing residential building. It is assimilated to a heat exchanger to allow its effectiveness to be studied as a function of the area and airflow rate. The balance between the energy consumed by the fan and the heat evacuated by the system is also studied through the use of the thermo-hydraulic performance factor (THPF), for which a series of cases were simulated by CFD following a methodology in which a configuration is achieved by means of the sequential analysis of cases in which both the thermal effectiveness and the THPF are maximized. The configuration chosen in this study was found to benefit from high airflow rates since, although this implies an increase in fan energy consumption, the increase in heat removed is proportionally greater. It has also been found that the design of the airflow distribution through the slab is of high importance as it affects both the heat exchanged with the slab and the pressure losses. An applicability map has been developed as a function of the temperature of the space below and the air temperature at the inlet of the ventilated roof. The heat flux per unit area that the studied envelope is able to evacuate is about 20 W/m2 K. [ABSTRACT FROM AUTHOR]
Copyright of Applied Sciences (2076-3417) is the property of MDPI and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20763417
DOI:10.3390/app14156596