Academic Journal

Early Institutional Experience with One-Piece Bifurcated-Fenestrated Stentgraft in the Treatment of Abdominal Aortic Aneurysms.

التفاصيل البيبلوغرافية
العنوان: Early Institutional Experience with One-Piece Bifurcated-Fenestrated Stentgraft in the Treatment of Abdominal Aortic Aneurysms.
المؤلفون: Mesnard, Thomas, Pruvot, Louis, Oliver Patterson, Benjamin, Préville, Agathe De, Azzaoui, Richard, Sobocinski, Jonathan
المصدر: Journal of Endovascular Therapy; Apr2024, Vol. 31 Issue 2, p241-247, 7p
مستخلص: Purpose: To review the early experience of the use of a bifurcated-fenestrated endograft (Bif-FEVAR) to treat abdominal aortic aneurysms (AAA) in a high-volume aortic center. Methods: A retrospective single-center analysis was conducted between March 2019 and April 2021 including consecutive patients that underwent Bif-FEVAR. Only patients without a proper infrarenal neck and a distance <70 mm between the lowest target artery and the native or prosthetic aortic bifurcation were considered. All Bif-FEVAR custom-made devices were manufactured by Cook Medical (Inc., Bloomington, Indiana). Demographics, anatomical features, technical success, major adverse events, 30-day mortality, and survival according to Kaplan–Meier were analyzed according to Society for Vascular Surgery standards. Results: Overall, 10 patients (100% male with median age 78) were included. The median preoperative maximal aneurysm diameter was 68 mm [51–84]. Eight patients were treated for a proximal type I endoleak after endovascular aneurysm repair. A total of 36 fenestrations were planned. The median operative time was 144 min [127–168], with a median fluoro time of 40.5 min [34–54] and a median dose area product of 73 Gy cm2 [61–89]. Technical success rate was 100%. No patients experienced a major postoperative adverse event. Median follow-up time was 8 months [6–13]. Conclusion: Bif-FEVAR is technically feasible when there is a short distance below the lowest target artery and the aortic bifurcation, with favorable short-term results. Clinical Impact: This study assessed the use of an innovative one-piece bifurcated fenestrated stent-graft as a primary procedure or in the treatment of proximal endoleak after standard infrarenal EVAR. We demonstrated these custom-made devices can be used safely with favorable short-term results. One-piece bifurcated fenestrated stent-grafts extend the indications of FEVAR for patients with an unusually short distance between the lowest renal artery and the aorto-iliac bifurcation or the diverter flow of a preexisting bifurcated infrarenal stent-graft. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Endovascular Therapy is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:15266028
DOI:10.1177/15266028221119612