التفاصيل البيبلوغرافية
العنوان: |
Comparing the diagnostic accuracy, reading time, and inter-rater agreement of breast MRI abbreviated and full protocols: a multi-reader study. |
المؤلفون: |
Hellgren, Roxanna, Tolocka, Ernst, Saracco, Ariel, Wilczek, Brigitte, Sundbom, Ann, Hall, Per, Dickman, Paul W |
المصدر: |
Acta Radiologica; Feb2024, Vol. 65 Issue 2, p195-201, 7p |
مصطلحات موضوعية: |
MAGNETIC resonance imaging, GENERALIZED estimating equations, CANCER diagnosis |
مستخلص: |
Background: Earlier studies have shown that abbreviated protocol magnetic resonance imaging (AB-MRI) has similar diagnostic accuracy as the full protocol (Full MRI). Purpose: To compare the diagnostic accuracy, reading time, and inter-rater agreement of AB-MRI to Full MRI among women without known increased familial risk of breast cancer or prior biopsy. Material and Methods: In total, 395 MRI examinations were included in this study. Three readers were blinded to all patient information. The AB-MRI and Full MRI were read separately and in a different random order for each of the readers. Scores 1–2 were considered test negative while scores 3–5 were test positive. A positive reference test was the diagnosis of malignancy; a negative reference test was the absence of a diagnosis of breast cancer within a two-year follow-up. We used a generalized estimating equations approach to compare sensitivity and specificity between the two protocols. We used t -tests to compare the average reading time and Krippendorff's alpha to compare inter-rater agreement. Results: MRI examinations of 395 women (median age=56 years) were evaluated. For AB-MRI and Full MRI, respectively, the sensitivity was 93.0% (95% CI=90.6–95.0) vs. 92.0% (95% CI=89.4–94.1), the specificity was 91.7% (95% CI=90.3–92.9) vs. 94.3% (95% CI=93.2–95.3), average reading time was 67 vs. 126 s, and the inter-rater agreement 0.79 vs. 0.83. The difference in sensitivity was not statistically significant (P =0.840), but the difference in specificity was significant (P =0.003). Conclusion: AB-MRI has similar sensitivity, but somewhat lower specificity. The average reading time for the abbreviated protocol is lower, as is inter-rater agreement. [ABSTRACT FROM AUTHOR] |
|
Copyright of Acta Radiologica is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |
قاعدة البيانات: |
Complementary Index |