Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study.

التفاصيل البيبلوغرافية
العنوان: Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: a retrospective study.
المؤلفون: Mancino, Fabio, Rossi, Stefano Marco Paolo, Sangaletti, Rudy, Caredda, Matteo, Terragnoli, Flavio, Benazzo, Francesco
المصدر: Archives of Orthopaedic & Trauma Surgery; Jan2024, Vol. 144 Issue 1, p393-404, 12p
مصطلحات موضوعية: TOTAL knee replacement, FEMUR, ANATOMICAL planes, ROBOTICS, RETROSPECTIVE studies
مستخلص: Background: Robotic-assisted total knee arthroplasty (RTKA) and navigated total knee arthroplasty (NTKA) have shown improved knee alignment and reduced radiographic outliers. Recent studies have proven that conventional mechanical alignment may not be the optimal goal for every patient. The aim of this study was to compare the accuracy of the planned implant positioning of a novel image-less robotic technique with an established navigated technique (NTKA). Method: The study is a retrospective analysis of prospectively collected data that compared the implant positioning and lower-limb alignment of 86 image-less RTKA with 86 image-less NTKA. Radiographic analysis was performed to evaluate the lower-limb overall alignment, femoral and tibial components positioning in the coronal and sagittal planes. Outliers were evaluated with a cutoff of ± 3°. Results: No difference was noted between the two groups for radiographic outliers within ± 3° from neutral (p = 0.098). The mean hip–knee–ankle angle deviation from target was 1.3° in the RTKA group compared to 1.9° in the NTKA (p < 0.001). Femoral sagittal deviation (femoral component flexion) was smaller in the RTKA group (0.9° vs 1.9°; p < 0.001). Similarly, tibial coronal deviation (0.8° vs 1.5°; p < 0.001) and tibial sagittal deviation (tibial slope) were smaller in the RTKA group compared to the NTKA group (0.9° vs 1.7°; p < 0.001). Conclusions: The RTKA group reported a substantial and significant reduced error from the planned target angles for both tibial and femoral components. No difference in terms of radiographic outliers was noted between navigation and robotic assistance. [ABSTRACT FROM AUTHOR]
Copyright of Archives of Orthopaedic & Trauma Surgery is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09368051
DOI:10.1007/s00402-023-05062-y