التفاصيل البيبلوغرافية
العنوان: |
DQE and eDQE of the KARS-BKS2 Digital Slot Scan X-Ray System. |
المؤلفون: |
Bekhterev, A. V., Kotkov, R. V., Labusov, V. A., Lokhtin, R. A., P'yanov, D. A., Strokov, I. I., Khramov, M. S. |
المصدر: |
Biomedical Engineering; Sep2021, Vol. 55 Issue 3, p204-209, 6p |
مصطلحات موضوعية: |
X-rays, COMPUTERS in medicine, CINERADIOGRAPHY, MEDICAL databases, INFORMATION storage & retrieval systems, PHOTON absorptiometry, DIGITAL technology, AUDITORY perception, RADIATION, DIAGNOSTIC imaging, DOSIMETERS, RADIATION doses, DATA analysis software, DIGITAL diagnostic imaging, SCANNING systems, EQUIPMENT & supplies |
مستخلص: |
DQE and eDQE were evaluated for a slot scan X-ray system using four standard radiation qualities: RQA3, RQA5, RQA7, and RQA9. The results showed that the system under consideration, KARS-BKS2 fluorograph, provided maximal DQE(u,v) and eDQE(u′,v′) in the case of radiation quality RQA5 and a small focal point. At null spatial frequencies DQE(0) was greater than 40% and eDQE(0) was 35%. [ABSTRACT FROM AUTHOR] |
|
Copyright of Biomedical Engineering is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.) |