234-OR: Postprandial Glucose Control Using the Medtronic Advanced Hybrid Closed-Loop System: Faster-Acting Insulin Aspart vs. Insulin Aspart.

التفاصيل البيبلوغرافية
العنوان: 234-OR: Postprandial Glucose Control Using the Medtronic Advanced Hybrid Closed-Loop System: Faster-Acting Insulin Aspart vs. Insulin Aspart.
المؤلفون: LEE, MELISSA H., VOGRIN, SARA, PALDUS, BARBORA, MORRISON, DALE, ZAHARIEVA, DESSI, LU, JEAN, JONES, HANNAH, WYATT, SUE A., NETZER, EMMA, SIMS, CATRIONA M., MACISAAC, RICHARD, GROSMAN, BENYAMIN, ROY, ANIRBAN, KURTZ, NATALIE, JENKINS, ALICIA, ONEAL, DAVID N.
المصدر: Diabetes; 2020 Supplement, Vol. 69, pN.PAG-N.PAG, 1p
مستخلص: Background: Faster-acting insulin aspart (FiAsp) may improve responsiveness of closed-loop (CL) systems and provide better postprandial glucose (PPG) management due to its more rapid onset and offset compared to insulin aspart (Asp). The Medtronic Advanced Hybrid Closed Loop (AHCL) System features auto-basal and auto-bolus functions. Aim: To compare PPG control using FiAsp vs. Asp delivered using AHCL. Methods: Twelve adults with T1D (median HbA1c 7.1% [IQR 6.8, 7.2]; 54mmol/mol [51, 55]) were assigned to FiAsp or Asp (unblinded) in random-order over two-stages (6-weeks duration each) using AHCL. Postprandial periods were defined using set time-blocks for breakfast (06:00-10:00); lunch (11:00-15:00); and dinner (17:00-21:00), based on conventional meal-times and meal distribution. CGM data was analyzed using signed-rank test. Results: With all postprandial time-block data aggregated, FiAsp demonstrated greater overall time-in-range (TIR) (70-180mg/dL) (p=0.028) and less hyperglycaemia (p=0.041) compared with Asp (Table). TIR was greater during lunch (p=0.034) for FiAsp vs. Asp, with no difference during breakfast or dinner. Over the 6-week duration, FiAsp use trended towards greater TIR vs. Asp (82.7% vs. 80.4%, p=0.07). Conclusions: FiAsp appears to confer an advantage compared with Asp for PPG control whilst using AHCL even in subjects with high overall TIR. Disclosure: M.H. Lee: Research Support; Self; Medtronic. Speaker's Bureau; Self; AstraZeneca, Medtronic. S. Vogrin: None. B. Paldus: Research Support; Self; JDRF. Speaker's Bureau; Self; Australian Diabetes Society, Medtronic. D. Morrison: None. D. Zaharieva: Speaker's Bureau; Self; Ascensia Diabetes Care, Insulet Corporation, Medtronic. J. Lu: None. H. Jones: None. S.A. Wyatt: Other Relationship; Self; Medtronic, Ypsomed AG. E. Netzer: None. C.M. Sims: Stock/Shareholder; Self; Medtronic. R. MacIsaac: None. B. Grosman: Employee; Self; Medtronic. A. Roy: Employee; Self; Medtronic. N. Kurtz: Employee; Self; Medtronic. A. Jenkins: Advisory Panel; Self; Abbott, Medtronic. Research Support; Self; Abbott, GlySens Incorporated, Medtronic, Sanofi-Aventis. D.N. ONeal: None. [ABSTRACT FROM AUTHOR]
Copyright of Diabetes is the property of American Diabetes Association and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00121797
DOI:10.2337/db20-234-OR