Academic Journal

The low‐cost Shifter microscope stage transforms the speed and robustness of protein crystal harvesting.

التفاصيل البيبلوغرافية
العنوان: The low‐cost Shifter microscope stage transforms the speed and robustness of protein crystal harvesting.
المؤلفون: Wright, Nathan David, Collins, Patrick, Koekemoer, Lizbé, Krojer, Tobias, Talon, Romain, Nelson, Elliot, Ye, Mingda, Nowak, Radosław, Newman, Joseph, Ng, Jia Tsing, Mitrovich, Nick, Wiggers, Helton, von Delft, Frank
المصدر: Acta Crystallographica: Section D, Structural Biology; Jan2021, Vol. 77 Issue 1, p62-74, 13p
مصطلحات موضوعية: CRYSTALLOIDS (Botany), PROTEIN crystallography, FINE motor ability, MICROSCOPES, LIGHT sources
مستخلص: Despite the tremendous success of X‐ray cryo‐crystallography in recent decades, the transfer of crystals from the drops in which they are grown to diffractometer sample mounts remains a manual process in almost all laboratories. Here, the Shifter, a motorized, interactive microscope stage that transforms the entire crystal‐mounting workflow from a rate‐limiting manual activity to a controllable, high‐throughput semi‐automated process, is described. By combining the visual acuity and fine motor skills of humans with targeted hardware and software automation, it was possible to transform the speed and robustness of crystal mounting. Control software, triggered by the operator, manoeuvres crystallization plates beneath a clear protective cover, allowing the complete removal of film seals and thereby eliminating the tedium of repetitive seal cutting. The software, either upon request or working from an imported list, controls motors to position crystal drops under a hole in the cover for human mounting at a microscope. The software automatically captures experimental annotations for uploading to the user's data repository, removing the need for manual documentation. The Shifter facilitates mounting rates of 100–240 crystals per hour in a more controlled process than manual mounting, which greatly extends the lifetime of the drops and thus allows a dramatic increase in the number of crystals retrievable from any given drop without loss of X‐ray diffraction quality. In 2015, the first in a series of three Shifter devices was deployed as part of the XChem fragment‐screening facility at Diamond Light Source, where they have since facilitated the mounting of over 120 000 crystals. The Shifter was engineered to have a simple design, providing a device that could be readily commercialized and widely adopted owing to its low cost. The versatile hardware design allows use beyond fragment screening and protein crystallography. [ABSTRACT FROM AUTHOR]
Copyright of Acta Crystallographica: Section D, Structural Biology is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09074449
DOI:10.1107/S2059798320014114