Academic Journal

Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers

التفاصيل البيبلوغرافية
العنوان: Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers
المؤلفون: Salahaldeen Abuhammoud, Banan Emtier, Chin-Chuan Fu, Silvia Rojas-Rueda, Carlos A. Jurado, Kelvin I. Afrashtehfar
المصدر: Saudi Dental Journal, Vol 36, Iss 6, Pp 920-925 (2024)
بيانات النشر: Elsevier, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
LCC:Dentistry
مصطلحات موضوعية: Dental veneers, Dental materials, Dental prosthesis design, Fracture resistance, CAD/CAM systems, Provisional restorations, Medicine, Dentistry, RK1-715
الوصف: Background: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed. Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers. Materials and methods: Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M). The restorations were cemented onto 3D-printed resin dies using temporary cement and subjected to 1000 cycles of thermal cycling between 5° and 55 °C. These restorations subsequently were subjected to compressive loading until fracture occurred. Images of the fractured samples were captured using a scanning electron microscope (SEM). Statistical analysis was performed using the one-way ANOVA test and the Mann-Whitney U test. Results: Significant differences (p
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1013-9052
Relation: http://www.sciencedirect.com/science/article/pii/S101390522400124X; https://doaj.org/toc/1013-9052
DOI: 10.1016/j.sdentj.2024.04.002
URL الوصول: https://doaj.org/article/fafe31bf6d634e73ad332c810d4c572e
رقم الانضمام: edsdoj.fafe31bf6d634e73ad332c810d4c572e
قاعدة البيانات: Directory of Open Access Journals
ResultId 1
Header edsdoj
Directory of Open Access Journals
edsdoj.fafe31bf6d634e73ad332c810d4c572e
1047
3
Academic Journal
academicJournal
1047.21545410156
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.fafe31bf6d634e73ad332c810d4c572e&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://doaj.org/article/fafe31bf6d634e73ad332c810d4c572e [Name] => EDS - DOAJ [Category] => fullText [Text] => View record in DOAJ [MouseOverText] => View record in DOAJ ) [1] => Array ( [Url] => https://resolver.ebscohost.com/openurl?custid=s6537998&groupid=main&authtype=ip,guest&sid=EBSCO:edsdoj&genre=article&issn=10139052&ISBN=&volume=36&issue=6&date=20240601&spage=920&pages=920-925&title=Saudi Dental Journal&atitle=Fracture%20resistance%20of%20CAD%2FCAM%20milled%20versus%20direct%20hand-made%20interim%20laminate%20veneers&id=DOI:10.1016/j.sdentj.2024.04.002 [Name] => Full Text Finder (s6537998api) [Category] => fullText [Text] => Full Text Finder [Icon] => https://imageserver.ebscohost.com/branding/images/FTF.gif [MouseOverText] => Full Text Finder ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Salahaldeen+Abuhammoud%22">Salahaldeen Abuhammoud</searchLink><br /><searchLink fieldCode="AR" term="%22Banan+Emtier%22">Banan Emtier</searchLink><br /><searchLink fieldCode="AR" term="%22Chin-Chuan+Fu%22">Chin-Chuan Fu</searchLink><br /><searchLink fieldCode="AR" term="%22Silvia+Rojas-Rueda%22">Silvia Rojas-Rueda</searchLink><br /><searchLink fieldCode="AR" term="%22Carlos+A%2E+Jurado%22">Carlos A. Jurado</searchLink><br /><searchLink fieldCode="AR" term="%22Kelvin+I%2E+Afrashtehfar%22">Kelvin I. Afrashtehfar</searchLink> )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => Saudi Dental Journal, Vol 36, Iss 6, Pp 920-925 (2024) )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => Elsevier, 2024. )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2024 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => LCC:Medicine<br />LCC:Dentistry )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Dental+veneers%22">Dental veneers</searchLink><br /><searchLink fieldCode="DE" term="%22Dental+materials%22">Dental materials</searchLink><br /><searchLink fieldCode="DE" term="%22Dental+prosthesis+design%22">Dental prosthesis design</searchLink><br /><searchLink fieldCode="DE" term="%22Fracture+resistance%22">Fracture resistance</searchLink><br /><searchLink fieldCode="DE" term="%22CAD%2FCAM+systems%22">CAD/CAM systems</searchLink><br /><searchLink fieldCode="DE" term="%22Provisional+restorations%22">Provisional restorations</searchLink><br /><searchLink fieldCode="DE" term="%22Medicine%22">Medicine</searchLink><br /><searchLink fieldCode="DE" term="%22Dentistry%22">Dentistry</searchLink><br /><searchLink fieldCode="DE" term="%22RK1-715%22">RK1-715</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => Background: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed. Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers. Materials and methods: Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M). The restorations were cemented onto 3D-printed resin dies using temporary cement and subjected to 1000 cycles of thermal cycling between 5° and 55 °C. These restorations subsequently were subjected to compressive loading until fracture occurred. Images of the fractured samples were captured using a scanning electron microscope (SEM). Statistical analysis was performed using the one-way ANOVA test and the Mann-Whitney U test. Results: Significant differences (p )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article )
Array ( [Name] => Format [Label] => File Description [Group] => SrcInfo [Data] => electronic resource )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English )
Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 1013-9052 )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => http://www.sciencedirect.com/science/article/pii/S101390522400124X; https://doaj.org/toc/1013-9052 )
Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1016/j.sdentj.2024.04.002 )
Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://doaj.org/article/fafe31bf6d634e73ad332c810d4c572e" linkWindow="_blank">https://doaj.org/article/fafe31bf6d634e73ad332c810d4c572e</link> )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsdoj.fafe31bf6d634e73ad332c810d4c572e )
RecordInfo Array ( [BibEntity] => Array ( [Identifiers] => Array ( [0] => Array ( [Type] => doi [Value] => 10.1016/j.sdentj.2024.04.002 ) ) [Languages] => Array ( [0] => Array ( [Text] => English ) ) [PhysicalDescription] => Array ( [Pagination] => Array ( [PageCount] => 6 [StartPage] => 920 ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Dental veneers [Type] => general ) [1] => Array ( [SubjectFull] => Dental materials [Type] => general ) [2] => Array ( [SubjectFull] => Dental prosthesis design [Type] => general ) [3] => Array ( [SubjectFull] => Fracture resistance [Type] => general ) [4] => Array ( [SubjectFull] => CAD/CAM systems [Type] => general ) [5] => Array ( [SubjectFull] => Provisional restorations [Type] => general ) [6] => Array ( [SubjectFull] => Medicine [Type] => general ) [7] => Array ( [SubjectFull] => Dentistry [Type] => general ) [8] => Array ( [SubjectFull] => RK1-715 [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Salahaldeen Abuhammoud ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Banan Emtier ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Chin-Chuan Fu ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Silvia Rojas-Rueda ) ) ) [4] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Carlos A. Jurado ) ) ) [5] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Kelvin I. Afrashtehfar ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 06 [Type] => published [Y] => 2024 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 10139052 ) ) [Numbering] => Array ( [0] => Array ( [Type] => volume [Value] => 36 ) [1] => Array ( [Type] => issue [Value] => 6 ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Saudi Dental Journal [Type] => main ) ) ) ) ) ) )
IllustrationInfo