Academic Journal
A risk-based, distributed sensor installation concept for high voltage grid monitoring
العنوان: | A risk-based, distributed sensor installation concept for high voltage grid monitoring |
---|---|
المؤلفون: | Levente Rácz, Bálint Németh, Gábor Göcsei |
المصدر: | Energy Reports, Vol 8, Iss , Pp 266-274 (2022) |
بيانات النشر: | Elsevier, 2022. |
سنة النشر: | 2022 |
المجموعة: | LCC:Electrical engineering. Electronics. Nuclear engineering |
مصطلحات موضوعية: | Dynamic line rating, DLR, Line monitoring sensor, High voltage power lines, Installation method, Monte Carlo sampling, Electrical engineering. Electronics. Nuclear engineering, TK1-9971 |
الوصف: | This paper presents a novel installation protocol to build a reliable and economical line monitoring system on high voltage power lines. The proposed method is able to iteratively determine the required number of sensors and their installation location for a predefined level of risk. First, it requires a general analysis of the transmission line, which ends with a critical span analysis. Then the risk arising from the variability of weather parameters along the transmission line must be determined. Finally, it is necessary to consider what kind of problem the thermal overheating can cause at the conductor (sagging, annealing) and which additional stages can be used to reduce the risk factor to the permissible level. A case study was investigated with the data of a Central-European high voltage power line to present how the proposed method works. The results showed that there are power lines on which only distributed sensor installation concepts result in a safe and economical solution. Applying the proposed method, a comprehensive and robust sensor system can be implemented, which can be a solid basis for any dynamic line rating (DLR) system. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2352-4847 |
Relation: | http://www.sciencedirect.com/science/article/pii/S2352484721012476; https://doaj.org/toc/2352-4847 |
DOI: | 10.1016/j.egyr.2021.11.102 |
URL الوصول: | https://doaj.org/article/bca2cc4301c14d4f8c392ff7fa8ce660 |
رقم الانضمام: | edsdoj.bca2cc4301c14d4f8c392ff7fa8ce660 |
قاعدة البيانات: | Directory of Open Access Journals |
ResultId |
1 |
---|---|
Header |
edsdoj Directory of Open Access Journals edsdoj.bca2cc4301c14d4f8c392ff7fa8ce660 967 3 Academic Journal academicJournal 967.363525390625 |
PLink |
https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.bca2cc4301c14d4f8c392ff7fa8ce660&custid=s6537998&authtype=sso |
FullText |
Array
(
[Availability] => 0
)
Array ( [0] => Array ( [Url] => https://doaj.org/article/bca2cc4301c14d4f8c392ff7fa8ce660 [Name] => EDS - DOAJ [Category] => fullText [Text] => View record in DOAJ [MouseOverText] => View record in DOAJ ) [1] => Array ( [Url] => https://resolver.ebscohost.com/openurl?custid=s6537998&groupid=main&authtype=ip,guest&sid=EBSCO:edsdoj&genre=article&issn=23524847&ISBN=&volume=8&issue=266-274&date=20220401&spage=266&pages=266-274&title=Energy Reports&atitle=A%20risk-based%2C%20distributed%20sensor%20installation%20concept%20for%20high%20voltage%20grid%20monitoring&id=DOI:10.1016/j.egyr.2021.11.102 [Name] => Full Text Finder (s6537998api) [Category] => fullText [Text] => Full Text Finder [Icon] => https://imageserver.ebscohost.com/branding/images/FTF.gif [MouseOverText] => Full Text Finder ) ) |
Items |
Array
(
[Name] => Title
[Label] => Title
[Group] => Ti
[Data] => A risk-based, distributed sensor installation concept for high voltage grid monitoring
)
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Levente+Rácz%22">Levente Rácz</searchLink><br /><searchLink fieldCode="AR" term="%22Bálint+Németh%22">Bálint Németh</searchLink><br /><searchLink fieldCode="AR" term="%22Gábor+Göcsei%22">Gábor Göcsei</searchLink> ) Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => Energy Reports, Vol 8, Iss , Pp 266-274 (2022) ) Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => Elsevier, 2022. ) Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2022 ) Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => LCC:Electrical engineering. Electronics. Nuclear engineering ) Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Dynamic+line+rating%22">Dynamic line rating</searchLink><br /><searchLink fieldCode="DE" term="%22DLR%22">DLR</searchLink><br /><searchLink fieldCode="DE" term="%22Line+monitoring+sensor%22">Line monitoring sensor</searchLink><br /><searchLink fieldCode="DE" term="%22High+voltage+power+lines%22">High voltage power lines</searchLink><br /><searchLink fieldCode="DE" term="%22Installation+method%22">Installation method</searchLink><br /><searchLink fieldCode="DE" term="%22Monte+Carlo+sampling%22">Monte Carlo sampling</searchLink><br /><searchLink fieldCode="DE" term="%22Electrical+engineering%2E+Electronics%2E+Nuclear+engineering%22">Electrical engineering. Electronics. Nuclear engineering</searchLink><br /><searchLink fieldCode="DE" term="%22TK1-9971%22">TK1-9971</searchLink> ) Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => This paper presents a novel installation protocol to build a reliable and economical line monitoring system on high voltage power lines. The proposed method is able to iteratively determine the required number of sensors and their installation location for a predefined level of risk. First, it requires a general analysis of the transmission line, which ends with a critical span analysis. Then the risk arising from the variability of weather parameters along the transmission line must be determined. Finally, it is necessary to consider what kind of problem the thermal overheating can cause at the conductor (sagging, annealing) and which additional stages can be used to reduce the risk factor to the permissible level. A case study was investigated with the data of a Central-European high voltage power line to present how the proposed method works. The results showed that there are power lines on which only distributed sensor installation concepts result in a safe and economical solution. Applying the proposed method, a comprehensive and robust sensor system can be implemented, which can be a solid basis for any dynamic line rating (DLR) system. ) Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article ) Array ( [Name] => Format [Label] => File Description [Group] => SrcInfo [Data] => electronic resource ) Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English ) Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 2352-4847 ) Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => http://www.sciencedirect.com/science/article/pii/S2352484721012476; https://doaj.org/toc/2352-4847 ) Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1016/j.egyr.2021.11.102 ) Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://doaj.org/article/bca2cc4301c14d4f8c392ff7fa8ce660" linkWindow="_blank">https://doaj.org/article/bca2cc4301c14d4f8c392ff7fa8ce660</link> ) Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsdoj.bca2cc4301c14d4f8c392ff7fa8ce660 ) |
RecordInfo |
Array
(
[BibEntity] => Array
(
[Identifiers] => Array
(
[0] => Array
(
[Type] => doi
[Value] => 10.1016/j.egyr.2021.11.102
)
)
[Languages] => Array
(
[0] => Array
(
[Text] => English
)
)
[PhysicalDescription] => Array
(
[Pagination] => Array
(
[PageCount] => 9
[StartPage] => 266
)
)
[Subjects] => Array
(
[0] => Array
(
[SubjectFull] => Dynamic line rating
[Type] => general
)
[1] => Array
(
[SubjectFull] => DLR
[Type] => general
)
[2] => Array
(
[SubjectFull] => Line monitoring sensor
[Type] => general
)
[3] => Array
(
[SubjectFull] => High voltage power lines
[Type] => general
)
[4] => Array
(
[SubjectFull] => Installation method
[Type] => general
)
[5] => Array
(
[SubjectFull] => Monte Carlo sampling
[Type] => general
)
[6] => Array
(
[SubjectFull] => Electrical engineering. Electronics. Nuclear engineering
[Type] => general
)
[7] => Array
(
[SubjectFull] => TK1-9971
[Type] => general
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => A risk-based, distributed sensor installation concept for high voltage grid monitoring
[Type] => main
)
)
)
[BibRelationships] => Array
(
[HasContributorRelationships] => Array
(
[0] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Levente Rácz
)
)
)
[1] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Bálint Németh
)
)
)
[2] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Gábor Göcsei
)
)
)
)
[IsPartOfRelationships] => Array
(
[0] => Array
(
[BibEntity] => Array
(
[Dates] => Array
(
[0] => Array
(
[D] => 01
[M] => 04
[Type] => published
[Y] => 2022
)
)
[Identifiers] => Array
(
[0] => Array
(
[Type] => issn-print
[Value] => 23524847
)
)
[Numbering] => Array
(
[0] => Array
(
[Type] => volume
[Value] => 8
)
[1] => Array
(
[Type] => issue
[Value] => 266-274
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => Energy Reports
[Type] => main
)
)
)
)
)
)
)
|
IllustrationInfo |