Academic Journal

Contactless Engergy Supply for Medical Drill with Integrated Temperature Sensor

التفاصيل البيبلوغرافية
العنوان: Contactless Engergy Supply for Medical Drill with Integrated Temperature Sensor
المؤلفون: Knott Anna-Lena M. Sc., Sanders Mark M. Sc., Prinzen Tom, Klenzner Thomas, Schipper Jörg, Kristin Julia, Schmitt Robert H.
المصدر: Current Directions in Biomedical Engineering, Vol 10, Iss 2, Pp 79-82 (2024)
بيانات النشر: De Gruyter, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine
مصطلحات موضوعية: skull base surgery, medical drilling, temperature measurement, minimally invasive, contactless energy generation, Medicine
الوصف: An atraumatic approach to the inner ear is an important goal in the future development of cochlear implant surgery, as the current surgical procedure for electrode insertion is highly invasive. To reduce invasiveness, minimally invasive surgical options are being explored, such as the insertion of one or more drill channels. Due to the proximity to critical structures, a temperature sensor is incorporated into the medical drill for process parallel temperature monitoring to prevent thermal damage. The temperature data is sent to the analysis hardware via Bluetooth BLE. This requires a power supply for the electronics on the drill. There are a number of limitations to the design of such a power supply. For one, the drill is rotating. Therefore, the energy generation must be contactless. Secondly, the energy generation should not depend on the rotation of the drill, so that the temperature can be measured even without the drill rotating and the rotational speed of the drill is not limited. In this paper, we propose a solution for a contactless energy transmission system (ETS) based on inductive coupling. Considering the dimensional limitations of attaching the electronics to the drill shaft, a multilayer PCB coil with multiple contacts for different number of turns is developed. The electrical circuit is simulated and the best settings are identified. The power supply is validated according to the predefined requirements. In the future, the medical drill will be built with the newly developed ETS. Sterilization and wear tests are performed to confirm the suitability of the drill with integrated temperature sensor for the operating room.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2364-5504
Relation: https://doaj.org/toc/2364-5504
DOI: 10.1515/cdbme-2024-1072
URL الوصول: https://doaj.org/article/766433aa8ad34359b8a54bc5500d43d8
رقم الانضمام: edsdoj.766433aa8ad34359b8a54bc5500d43d8
قاعدة البيانات: Directory of Open Access Journals
ResultId 1
Header edsdoj
Directory of Open Access Journals
edsdoj.766433aa8ad34359b8a54bc5500d43d8
1063
3
Academic Journal
academicJournal
1063.00329589844
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsdoj&AN=edsdoj.766433aa8ad34359b8a54bc5500d43d8&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://doaj.org/article/766433aa8ad34359b8a54bc5500d43d8 [Name] => EDS - DOAJ [Category] => fullText [Text] => View record in DOAJ [MouseOverText] => View record in DOAJ ) [1] => Array ( [Url] => https://resolver.ebscohost.com/openurl?custid=s6537998&groupid=main&authtype=ip,guest&sid=EBSCO:edsdoj&genre=article&issn=23645504&ISBN=&volume=10&issue=2&date=20240901&spage=79&pages=79-82&title=Current Directions in Biomedical Engineering&atitle=Contactless%20Engergy%20Supply%20for%20Medical%20Drill%20with%20Integrated%20Temperature%20Sensor&id=DOI:10.1515/cdbme-2024-1072 [Name] => Full Text Finder (s6537998api) [Category] => fullText [Text] => Full Text Finder [Icon] => https://imageserver.ebscohost.com/branding/images/FTF.gif [MouseOverText] => Full Text Finder ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Contactless Engergy Supply for Medical Drill with Integrated Temperature Sensor )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Knott+Anna-Lena+M%2E+Sc%2E%22">Knott Anna-Lena M. Sc.</searchLink><br /><searchLink fieldCode="AR" term="%22Sanders+Mark+M%2E+Sc%2E%22">Sanders Mark M. Sc.</searchLink><br /><searchLink fieldCode="AR" term="%22Prinzen+Tom%22">Prinzen Tom</searchLink><br /><searchLink fieldCode="AR" term="%22Klenzner+Thomas%22">Klenzner Thomas</searchLink><br /><searchLink fieldCode="AR" term="%22Schipper+Jörg%22">Schipper Jörg</searchLink><br /><searchLink fieldCode="AR" term="%22Kristin+Julia%22">Kristin Julia</searchLink><br /><searchLink fieldCode="AR" term="%22Schmitt+Robert+H%2E%22">Schmitt Robert H.</searchLink> )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => Current Directions in Biomedical Engineering, Vol 10, Iss 2, Pp 79-82 (2024) )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => De Gruyter, 2024. )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2024 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => LCC:Medicine )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22skull+base+surgery%22">skull base surgery</searchLink><br /><searchLink fieldCode="DE" term="%22medical+drilling%22">medical drilling</searchLink><br /><searchLink fieldCode="DE" term="%22temperature+measurement%22">temperature measurement</searchLink><br /><searchLink fieldCode="DE" term="%22minimally+invasive%22">minimally invasive</searchLink><br /><searchLink fieldCode="DE" term="%22contactless+energy+generation%22">contactless energy generation</searchLink><br /><searchLink fieldCode="DE" term="%22Medicine%22">Medicine</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => An atraumatic approach to the inner ear is an important goal in the future development of cochlear implant surgery, as the current surgical procedure for electrode insertion is highly invasive. To reduce invasiveness, minimally invasive surgical options are being explored, such as the insertion of one or more drill channels. Due to the proximity to critical structures, a temperature sensor is incorporated into the medical drill for process parallel temperature monitoring to prevent thermal damage. The temperature data is sent to the analysis hardware via Bluetooth BLE. This requires a power supply for the electronics on the drill. There are a number of limitations to the design of such a power supply. For one, the drill is rotating. Therefore, the energy generation must be contactless. Secondly, the energy generation should not depend on the rotation of the drill, so that the temperature can be measured even without the drill rotating and the rotational speed of the drill is not limited. In this paper, we propose a solution for a contactless energy transmission system (ETS) based on inductive coupling. Considering the dimensional limitations of attaching the electronics to the drill shaft, a multilayer PCB coil with multiple contacts for different number of turns is developed. The electrical circuit is simulated and the best settings are identified. The power supply is validated according to the predefined requirements. In the future, the medical drill will be built with the newly developed ETS. Sterilization and wear tests are performed to confirm the suitability of the drill with integrated temperature sensor for the operating room. )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article )
Array ( [Name] => Format [Label] => File Description [Group] => SrcInfo [Data] => electronic resource )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English )
Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 2364-5504 )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => https://doaj.org/toc/2364-5504 )
Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1515/cdbme-2024-1072 )
Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://doaj.org/article/766433aa8ad34359b8a54bc5500d43d8" linkWindow="_blank">https://doaj.org/article/766433aa8ad34359b8a54bc5500d43d8</link> )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsdoj.766433aa8ad34359b8a54bc5500d43d8 )
RecordInfo Array ( [BibEntity] => Array ( [Identifiers] => Array ( [0] => Array ( [Type] => doi [Value] => 10.1515/cdbme-2024-1072 ) ) [Languages] => Array ( [0] => Array ( [Text] => English ) ) [PhysicalDescription] => Array ( [Pagination] => Array ( [PageCount] => 4 [StartPage] => 79 ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => skull base surgery [Type] => general ) [1] => Array ( [SubjectFull] => medical drilling [Type] => general ) [2] => Array ( [SubjectFull] => temperature measurement [Type] => general ) [3] => Array ( [SubjectFull] => minimally invasive [Type] => general ) [4] => Array ( [SubjectFull] => contactless energy generation [Type] => general ) [5] => Array ( [SubjectFull] => Medicine [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Contactless Engergy Supply for Medical Drill with Integrated Temperature Sensor [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Knott Anna-Lena M. Sc. ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Sanders Mark M. Sc. ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Prinzen Tom ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Klenzner Thomas ) ) ) [4] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Schipper Jörg ) ) ) [5] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Kristin Julia ) ) ) [6] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Schmitt Robert H. ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 09 [Type] => published [Y] => 2024 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 23645504 ) ) [Numbering] => Array ( [0] => Array ( [Type] => volume [Value] => 10 ) [1] => Array ( [Type] => issue [Value] => 2 ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Current Directions in Biomedical Engineering [Type] => main ) ) ) ) ) ) )
IllustrationInfo