Academic Journal

Are all robotic technologies created equal? Comparing one of the latest image-free robotic technologies to all other robotic systems for total knee arthroplasty

التفاصيل البيبلوغرافية
العنوان: Are all robotic technologies created equal? Comparing one of the latest image-free robotic technologies to all other robotic systems for total knee arthroplasty
المؤلفون: Philip Huang, Michael Cross, Anshu Gupta, Dhara Intwala, Jill Ruppenkamp, Daniel Hoeffel
المصدر: Journal of Orthopaedic Surgery and Research, Vol 19, Iss 1, Pp 1-9 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Orthopedic surgery
LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: VELYS, Robotic surgery, VRAS, Total knee arthroplasty, Readmission, Revision, Orthopedic surgery, RD701-811, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background Robotic-assisted technologies have been developed to increase surgical precision and reduce surgical variability in total knee arthroplasty (TKA). Several different robotic systems have been introduced in the last decade for TKA. The DePuy Synthes VELYS™ Robotic-Assisted Solution (VRAS) is an imageless system designed to eliminate the need for preoperative CT scans and is one of the latest entrants in the rapidly evolving field of robotic technology in TKA. This study compared the clinical and economic outcomes associated with VRAS and other robotic-assisted technologies for primary TKA. Methods A retrospective cohort study using the Premier Healthcare Database included patients who underwent primary TKA with VRAS or other robotic-assisted technologies from January 1, 2022, to April 30, 2023. The primary outcome for the study was hospital follow-up visits (revisits) within 90 days post-TKA. Secondary outcomes included readmission and revision rates within 90 days post-TKA, operating room time, length of stay, discharge status and hospital costs. Cohorts were balanced using propensity score fine stratification, and generalized linear models were constructed to evaluate outcomes. Results This study included 827 VRAS TKA patients and 16,428 TKA patients treated with other robotic-assisted technologies. The 90-day all-cause and knee-related revisit rates were significantly lower for VRAS than for other robotic-assisted technologies (all-cause 13.9% vs. 22.8% and knee-related 2.8% vs. 5.4%, respectively; p value
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1749-799X
Relation: https://doaj.org/toc/1749-799X
DOI: 10.1186/s13018-024-05150-8
URL الوصول: https://doaj.org/article/a23e0ee06b28437dbe0f9a7df2c486d2
رقم الانضمام: edsdoj.23e0ee06b28437dbe0f9a7df2c486d2
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1749799X
DOI:10.1186/s13018-024-05150-8