Academic Journal
Effect of Remixing & Intermittent Curing Sequences on Strength of Pavement Quality Concrete
العنوان: | Effect of Remixing & Intermittent Curing Sequences on Strength of Pavement Quality Concrete |
---|---|
المؤلفون: | Vishal B Shinde, Rakesh Kumar |
المساهمون: | Blue Eyes Intelligence Engineering & Sciences Publication(BEIESP) |
المصدر: | International Journal of Engineering and Advanced Technology (IJEAT), 9(4), 2000-2013, (2020-04-30) |
بيانات النشر: | Zenodo |
سنة النشر: | 2020 |
المجموعة: | Zenodo |
مصطلحات موضوعية: | Cold joint, intermittent curing, blend ratio, Time lag |
الوصف: | The paper is concerned with determining the effect of remixing of two different grades of concrete proving blend ratio, time lag & intermittent curing sequence. Two mix designs (M40 & M50) selected and provide blend ratio (0 to infinity) at 0,30,60,90 & 120min time lag. In this research, the problem related to improper casting & curing sequence, which ultimate formation of the cold joint due to old and fresh concrete. Curing method applied with four sequences Air0 Water28, Air28 Water0, Air7 Water21, and Air21 Water7.Concrete samples were made and tested for their compressive strength, flexural strength, elastic modulus, and shrinkage properties in the laboratory. As compared to the strength of freshly prepared concretes to the hard in situ concrete tends to show a reduction in its various strengths due to improper curing & formation of cold joints. This reduction is further possible to be minimized to a certain extent on blending some quantity of a relatively fresh mix to the existing quantity of the hard in situ concrete. |
نوع الوثيقة: | article in journal/newspaper |
اللغة: | English |
تدمد: | 2249-8958 |
Relation: | https://doi.org/10.35940/ijeat.D9086.049420; oai:zenodo.org:5563245 |
DOI: | 10.35940/ijeat.D9086.049420 |
الاتاحة: | https://doi.org/10.35940/ijeat.D9086.049420 |
Rights: | info:eu-repo/semantics/openAccess ; Creative Commons Attribution 4.0 International ; https://creativecommons.org/licenses/by/4.0/legalcode |
رقم الانضمام: | edsbas.F83601AA |
قاعدة البيانات: | BASE |
ResultId |
1 |
---|---|
Header |
edsbas BASE edsbas.F83601AA 905 3 Academic Journal academicJournal 905.017944335938 |
PLink |
https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.F83601AA&custid=s6537998&authtype=sso |
FullText |
Array
(
[Availability] => 0
)
Array ( [0] => Array ( [Url] => https://doi.org/10.35940/ijeat.D9086.049420# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) ) |
Items |
Array
(
[Name] => Title
[Label] => Title
[Group] => Ti
[Data] => Effect of Remixing & Intermittent Curing Sequences on Strength of Pavement Quality Concrete
)
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Vishal+B+Shinde%22">Vishal B Shinde</searchLink><br /><searchLink fieldCode="AR" term="%22Rakesh+Kumar%22">Rakesh Kumar</searchLink> ) Array ( [Name] => Author [Label] => Contributors [Group] => Au [Data] => Blue Eyes Intelligence Engineering & Sciences Publication(BEIESP) ) Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => International Journal of Engineering and Advanced Technology (IJEAT), 9(4), 2000-2013, (2020-04-30) ) Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => Zenodo ) Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2020 ) Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => Zenodo ) Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Cold+joint%22">Cold joint</searchLink><br /><searchLink fieldCode="DE" term="%22intermittent+curing%22">intermittent curing</searchLink><br /><searchLink fieldCode="DE" term="%22blend+ratio%22">blend ratio</searchLink><br /><searchLink fieldCode="DE" term="%22Time+lag%22">Time lag</searchLink> ) Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => The paper is concerned with determining the effect of remixing of two different grades of concrete proving blend ratio, time lag & intermittent curing sequence. Two mix designs (M40 & M50) selected and provide blend ratio (0 to infinity) at 0,30,60,90 & 120min time lag. In this research, the problem related to improper casting & curing sequence, which ultimate formation of the cold joint due to old and fresh concrete. Curing method applied with four sequences Air0 Water28, Air28 Water0, Air7 Water21, and Air21 Water7.Concrete samples were made and tested for their compressive strength, flexural strength, elastic modulus, and shrinkage properties in the laboratory. As compared to the strength of freshly prepared concretes to the hard in situ concrete tends to show a reduction in its various strengths due to improper curing & formation of cold joints. This reduction is further possible to be minimized to a certain extent on blending some quantity of a relatively fresh mix to the existing quantity of the hard in situ concrete. ) Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article in journal/newspaper ) Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English ) Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 2249-8958 ) Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => https://doi.org/10.35940/ijeat.D9086.049420; oai:zenodo.org:5563245 ) Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.35940/ijeat.D9086.049420 ) Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => https://doi.org/10.35940/ijeat.D9086.049420 ) Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => info:eu-repo/semantics/openAccess ; Creative Commons Attribution 4.0 International ; https://creativecommons.org/licenses/by/4.0/legalcode ) Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.F83601AA ) |
RecordInfo |
Array
(
[BibEntity] => Array
(
[Identifiers] => Array
(
[0] => Array
(
[Type] => doi
[Value] => 10.35940/ijeat.D9086.049420
)
)
[Languages] => Array
(
[0] => Array
(
[Text] => English
)
)
[Subjects] => Array
(
[0] => Array
(
[SubjectFull] => Cold joint
[Type] => general
)
[1] => Array
(
[SubjectFull] => intermittent curing
[Type] => general
)
[2] => Array
(
[SubjectFull] => blend ratio
[Type] => general
)
[3] => Array
(
[SubjectFull] => Time lag
[Type] => general
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => Effect of Remixing & Intermittent Curing Sequences on Strength of Pavement Quality Concrete
[Type] => main
)
)
)
[BibRelationships] => Array
(
[HasContributorRelationships] => Array
(
[0] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Vishal B Shinde
)
)
)
[1] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Rakesh Kumar
)
)
)
[2] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Blue Eyes Intelligence Engineering & Sciences Publication(BEIESP)
)
)
)
)
[IsPartOfRelationships] => Array
(
[0] => Array
(
[BibEntity] => Array
(
[Dates] => Array
(
[0] => Array
(
[D] => 01
[M] => 01
[Type] => published
[Y] => 2020
)
)
[Identifiers] => Array
(
[0] => Array
(
[Type] => issn-print
[Value] => 22498958
)
[1] => Array
(
[Type] => issn-locals
[Value] => edsbas
)
[2] => Array
(
[Type] => issn-locals
[Value] => edsbas.oa
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => International Journal of Engineering and Advanced Technology (IJEAT), 9(4), 2000-2013, (2020-04-30
[Type] => main
)
)
)
)
)
)
)
|
IllustrationInfo |