Academic Journal

Case studies on the use of LiveLink for MATLAB for evaluation and optimization of the heat sources in experimental borehole

التفاصيل البيبلوغرافية
العنوان: Case studies on the use of LiveLink for MATLAB for evaluation and optimization of the heat sources in experimental borehole
المؤلفون: Ožana, Štěpán, Hájovský, Radovan, Pieš, Martin, Martinek, Radek
بيانات النشر: MDPI
سنة النشر: 2020
المجموعة: DSpace VŠB-TUO (Vysoká škola báňská - Technická univerzita Ostrava / Technical University of Ostrava)
مصطلحات موضوعية: borehole heat exchanger (BHE), COMSOL multiphysics, LiveLink for MATLAB, MATLAB, optimization, partial differential equation
الوصف: In the Czech part of the Upper Silesian Coal Basin (Moravian-Silesian region, Czech Republic), there are many deposits of endogenous combustion (e.g., localized burning soil bodies, landfills containing industrial waste, or slag rocks caused by mining processes). The Hedwig mining dump represents such an example of these sites where, besides the temperature and the concentrations of toxic gases, electric and non-electric quantities are also monitored within the frame of experimentally proposed and patented technology for heat collection (the so-called "Pershing" system). Based on these quantities, this paper deals with the determination and evaluation of negative heat sources and the optimization of the positive heat source dependent on measured temperatures within evaluation points or on a thermal profile. The optimization problem is defined based on a balance of the heat sources in the steady state while searching for a local minimum of the objective function for the heat source. From an implementation point of view, it is the interconnection of the numerical model of the heat collector in COMSOL with a user optimization algorithm in MATLAB using the LiveLink for MATLAB. The results are elaborated in five case studies based on the susceptibility testing of the numerical model by input data from the evaluation points. The tests were focused on the model behavior in terms of preprocessing for measurement data from each chamber of the heat collector and for the estimated value of temperature differences at 90% and 110% of the nominal value. It turned out that the numerical model is more sensitive to the estimates in comparison with the measured data of the chambers, and this finding does not depend on the type optimization algorithm. The validation of the model by the use of the mean-square error led to the finding of optimal value, also valid with respect to the other evaluation. ; Web of Science ; 20 ; 5 ; art. no. 1297
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 1424-8220
Relation: Sensors; http://doi.org/10.3390/s20051297; Sensors. 2020, vol. 20, issue 5, art. no. 1297.; http://hdl.handle.net/10084/139465; 000525271500059
DOI: 10.3390/s20051297
الاتاحة: http://hdl.handle.net/10084/139465
https://doi.org/10.3390/s20051297
Rights: © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. ; http://creativecommons.org/licenses/by/4.0/ ; openAccess
رقم الانضمام: edsbas.E86BD842
قاعدة البيانات: BASE
ResultId 1
Header edsbas
BASE
edsbas.E86BD842
905
3
Academic Journal
academicJournal
905.017944335938
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.E86BD842&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => http://hdl.handle.net/10084/139465# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) [1] => Array ( [Url] => https://resolver.ebscohost.com/openurl?custid=s6537998&groupid=main&authtype=ip,guest&sid=EBSCO:edsbas&genre=article&issn=14248220&ISBN=&volume=&issue=&date=20200101&spage=&pages=&title=Case studies on the use of LiveLink for MATLAB for evaluation and optimization of the heat sources in experimental borehole&atitle=Case%20studies%20on%20the%20use%20of%20LiveLink%20for%20MATLAB%20for%20evaluation%20and%20optimization%20of%20the%20heat%20sources%20in%20experimental%20borehole&id=DOI:10.3390/s20051297 [Name] => Full Text Finder (s6537998api) [Category] => fullText [Text] => Full Text Finder [Icon] => https://imageserver.ebscohost.com/branding/images/FTF.gif [MouseOverText] => Full Text Finder ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Case studies on the use of LiveLink for MATLAB for evaluation and optimization of the heat sources in experimental borehole )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Ožana%2C+Štěpán%22">Ožana, Štěpán</searchLink><br /><searchLink fieldCode="AR" term="%22Hájovský%2C+Radovan%22">Hájovský, Radovan</searchLink><br /><searchLink fieldCode="AR" term="%22Pieš%2C+Martin%22">Pieš, Martin</searchLink><br /><searchLink fieldCode="AR" term="%22Martinek%2C+Radek%22">Martinek, Radek</searchLink> )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => MDPI )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2020 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => DSpace VŠB-TUO (Vysoká škola báňská - Technická univerzita Ostrava / Technical University of Ostrava) )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22borehole+heat+exchanger+%28BHE%29%22">borehole heat exchanger (BHE)</searchLink><br /><searchLink fieldCode="DE" term="%22COMSOL+multiphysics%22">COMSOL multiphysics</searchLink><br /><searchLink fieldCode="DE" term="%22LiveLink+for+MATLAB%22">LiveLink for MATLAB</searchLink><br /><searchLink fieldCode="DE" term="%22MATLAB%22">MATLAB</searchLink><br /><searchLink fieldCode="DE" term="%22optimization%22">optimization</searchLink><br /><searchLink fieldCode="DE" term="%22partial+differential+equation%22">partial differential equation</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => In the Czech part of the Upper Silesian Coal Basin (Moravian-Silesian region, Czech Republic), there are many deposits of endogenous combustion (e.g., localized burning soil bodies, landfills containing industrial waste, or slag rocks caused by mining processes). The Hedwig mining dump represents such an example of these sites where, besides the temperature and the concentrations of toxic gases, electric and non-electric quantities are also monitored within the frame of experimentally proposed and patented technology for heat collection (the so-called "Pershing" system). Based on these quantities, this paper deals with the determination and evaluation of negative heat sources and the optimization of the positive heat source dependent on measured temperatures within evaluation points or on a thermal profile. The optimization problem is defined based on a balance of the heat sources in the steady state while searching for a local minimum of the objective function for the heat source. From an implementation point of view, it is the interconnection of the numerical model of the heat collector in COMSOL with a user optimization algorithm in MATLAB using the LiveLink for MATLAB. The results are elaborated in five case studies based on the susceptibility testing of the numerical model by input data from the evaluation points. The tests were focused on the model behavior in terms of preprocessing for measurement data from each chamber of the heat collector and for the estimated value of temperature differences at 90% and 110% of the nominal value. It turned out that the numerical model is more sensitive to the estimates in comparison with the measured data of the chambers, and this finding does not depend on the type optimization algorithm. The validation of the model by the use of the mean-square error led to the finding of optimal value, also valid with respect to the other evaluation. ; Web of Science ; 20 ; 5 ; art. no. 1297 )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article in journal/newspaper )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English )
Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 1424-8220 )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => Sensors; http://doi.org/10.3390/s20051297; Sensors. 2020, vol. 20, issue 5, art. no. 1297.; http://hdl.handle.net/10084/139465; 000525271500059 )
Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.3390/s20051297 )
Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => http://hdl.handle.net/10084/139465<br />https://doi.org/10.3390/s20051297 )
Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. ; http://creativecommons.org/licenses/by/4.0/ ; openAccess )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.E86BD842 )
RecordInfo Array ( [BibEntity] => Array ( [Identifiers] => Array ( [0] => Array ( [Type] => doi [Value] => 10.3390/s20051297 ) ) [Languages] => Array ( [0] => Array ( [Text] => English ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => borehole heat exchanger (BHE) [Type] => general ) [1] => Array ( [SubjectFull] => COMSOL multiphysics [Type] => general ) [2] => Array ( [SubjectFull] => LiveLink for MATLAB [Type] => general ) [3] => Array ( [SubjectFull] => MATLAB [Type] => general ) [4] => Array ( [SubjectFull] => optimization [Type] => general ) [5] => Array ( [SubjectFull] => partial differential equation [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Case studies on the use of LiveLink for MATLAB for evaluation and optimization of the heat sources in experimental borehole [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Ožana, Štěpán ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Hájovský, Radovan ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Pieš, Martin ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Martinek, Radek ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 01 [Type] => published [Y] => 2020 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 14248220 ) [1] => Array ( [Type] => issn-locals [Value] => edsbas ) [2] => Array ( [Type] => issn-locals [Value] => edsbas.oa ) ) ) ) ) ) )
IllustrationInfo