Academic Journal
PET/CT acceptance testing and quality assurance: Executive summary of AAPM Task Group 126 Report
العنوان: | PET/CT acceptance testing and quality assurance: Executive summary of AAPM Task Group 126 Report |
---|---|
المؤلفون: | Lopez, Benjamin P., Jordan, David W., Kemp, Brad J., Kinahan, Paul E., Schmidtlein, Charles R., Mawlawi, Osama R. |
المصدر: | Medical Physics ; volume 48, issue 2 ; ISSN 0094-2405 2473-4209 |
بيانات النشر: | Wiley |
سنة النشر: | 2021 |
المجموعة: | Wiley Online Library (Open Access Articles via Crossref) |
الوصف: | Purpose A Positron Emission Tomography/Computed Tomography quality assurance program is necessary to ensure that patients receive optimal imaging and care. We summarize the AAPM Task Group (TG) 126 report on acceptance and quality assurance (QA) testing of PET/CT systems. Methods TG 126 was charged with developing PET/CT acceptance testing and QA procedures. The TG aimed to develop procedures that would allow for standardized evaluation of existing short‐axis cylindrical‐bore PET/CT systems in the spirit of NEMA NU 2 standards without requiring specialized phantoms or proprietary software tools. Results We outline eight performance evaluations using common phantoms and freely available software whereby the clinical physicist monitors each PET/CT system by comparing periodic Follow‐Up Measurements to Baseline Measurements acquired during acceptance testing. For each of the eight evaluations, we also summarize the expected testing time and materials necessary and the recommended pass/fail criteria. Conclusion Our report provides a guideline for periodic evaluations of most clinical PET/CT systems that simplifies procedures and requirements outlined by other agencies and will facilitate performance comparisons across vendors, models, and institutions. |
نوع الوثيقة: | article in journal/newspaper |
اللغة: | English |
DOI: | 10.1002/mp.14656 |
الاتاحة: | http://dx.doi.org/10.1002/mp.14656 https://onlinelibrary.wiley.com/doi/pdf/10.1002/mp.14656 https://onlinelibrary.wiley.com/doi/full-xml/10.1002/mp.14656 https://aapm.onlinelibrary.wiley.com/doi/pdf/10.1002/mp.14656 |
Rights: | http://onlinelibrary.wiley.com/termsAndConditions#vor |
رقم الانضمام: | edsbas.7AEE1DF1 |
قاعدة البيانات: | BASE |
ResultId |
1 |
---|---|
Header |
edsbas BASE edsbas.7AEE1DF1 919 3 Academic Journal academicJournal 918.9462890625 |
PLink |
https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.7AEE1DF1&custid=s6537998&authtype=sso |
FullText |
Array
(
[Availability] => 0
)
Array ( [0] => Array ( [Url] => http://dx.doi.org/10.1002/mp.14656# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) ) |
Items |
Array
(
[Name] => Title
[Label] => Title
[Group] => Ti
[Data] => PET/CT acceptance testing and quality assurance: Executive summary of AAPM Task Group 126 Report
)
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Lopez%2C+Benjamin+P%2E%22">Lopez, Benjamin P.</searchLink><br /><searchLink fieldCode="AR" term="%22Jordan%2C+David+W%2E%22">Jordan, David W.</searchLink><br /><searchLink fieldCode="AR" term="%22Kemp%2C+Brad+J%2E%22">Kemp, Brad J.</searchLink><br /><searchLink fieldCode="AR" term="%22Kinahan%2C+Paul+E%2E%22">Kinahan, Paul E.</searchLink><br /><searchLink fieldCode="AR" term="%22Schmidtlein%2C+Charles+R%2E%22">Schmidtlein, Charles R.</searchLink><br /><searchLink fieldCode="AR" term="%22Mawlawi%2C+Osama+R%2E%22">Mawlawi, Osama R.</searchLink> ) Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => Medical Physics ; volume 48, issue 2 ; ISSN 0094-2405 2473-4209 ) Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => Wiley ) Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2021 ) Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => Wiley Online Library (Open Access Articles via Crossref) ) Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => Purpose A Positron Emission Tomography/Computed Tomography quality assurance program is necessary to ensure that patients receive optimal imaging and care. We summarize the AAPM Task Group (TG) 126 report on acceptance and quality assurance (QA) testing of PET/CT systems. Methods TG 126 was charged with developing PET/CT acceptance testing and QA procedures. The TG aimed to develop procedures that would allow for standardized evaluation of existing short‐axis cylindrical‐bore PET/CT systems in the spirit of NEMA NU 2 standards without requiring specialized phantoms or proprietary software tools. Results We outline eight performance evaluations using common phantoms and freely available software whereby the clinical physicist monitors each PET/CT system by comparing periodic Follow‐Up Measurements to Baseline Measurements acquired during acceptance testing. For each of the eight evaluations, we also summarize the expected testing time and materials necessary and the recommended pass/fail criteria. Conclusion Our report provides a guideline for periodic evaluations of most clinical PET/CT systems that simplifies procedures and requirements outlined by other agencies and will facilitate performance comparisons across vendors, models, and institutions. ) Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article in journal/newspaper ) Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English ) Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1002/mp.14656 ) Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => http://dx.doi.org/10.1002/mp.14656<br />https://onlinelibrary.wiley.com/doi/pdf/10.1002/mp.14656<br />https://onlinelibrary.wiley.com/doi/full-xml/10.1002/mp.14656<br />https://aapm.onlinelibrary.wiley.com/doi/pdf/10.1002/mp.14656 ) Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => http://onlinelibrary.wiley.com/termsAndConditions#vor ) Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.7AEE1DF1 ) |
RecordInfo |
Array
(
[BibEntity] => Array
(
[Identifiers] => Array
(
[0] => Array
(
[Type] => doi
[Value] => 10.1002/mp.14656
)
)
[Languages] => Array
(
[0] => Array
(
[Text] => English
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => PET/CT acceptance testing and quality assurance: Executive summary of AAPM Task Group 126 Report
[Type] => main
)
)
)
[BibRelationships] => Array
(
[HasContributorRelationships] => Array
(
[0] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Lopez, Benjamin P.
)
)
)
[1] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Jordan, David W.
)
)
)
[2] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Kemp, Brad J.
)
)
)
[3] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Kinahan, Paul E.
)
)
)
[4] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Schmidtlein, Charles R.
)
)
)
[5] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Mawlawi, Osama R.
)
)
)
)
[IsPartOfRelationships] => Array
(
[0] => Array
(
[BibEntity] => Array
(
[Dates] => Array
(
[0] => Array
(
[D] => 01
[M] => 01
[Type] => published
[Y] => 2021
)
)
[Identifiers] => Array
(
[0] => Array
(
[Type] => issn-locals
[Value] => edsbas
)
[1] => Array
(
[Type] => issn-locals
[Value] => edsbas.oa
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => Medical Physics ; volume 48, issue 2 ; ISSN 0094-2405 2473-4209
[Type] => main
)
)
)
)
)
)
)
|
IllustrationInfo |