Is cellular energy monitoring more responsive to hypoxia than pulse oximetry?

التفاصيل البيبلوغرافية
العنوان: Is cellular energy monitoring more responsive to hypoxia than pulse oximetry?
المؤلفون: Liza H. Ashbrook, Aric A. Prather, Andrew D. Krystal, Guy M. Hatch
المصدر: Sleep & breathing = Schlaf & Atmung, vol 24, iss 4
Sleep & Breathing = Schlaf & Atmung
بيانات النشر: eScholarship, University of California, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Adult, Male, medicine.medical_specialty, Clinical Sciences, Respiratory System, Pilot Projects, Polysomnography, Primary snoring, 03 medical and health sciences, Wearable Electronic Devices, 0302 clinical medicine, Sleep Apnea Syndromes, Internal medicine, medicine, Humans, Cellular hypoxia, Psychology, Exertion, Oximetry, Hypoxia, Aged, Monitoring, Physiologic, medicine.diagnostic_test, business.industry, Sleep disordered breathing, Sleep Breathing Physiology and Disorders • Original Article, Blood flow, Cellular hyperoxia, Hypoxia (medical), Middle Aged, medicine.disease, Obstructive sleep apnea, Pulse oximetry, 030228 respiratory system, Otorhinolaryngology, Cardiology, Arterial blood, Female, Neurology (clinical), medicine.symptom, business, Energy Metabolism, Hypopnea, 030217 neurology & neurosurgery, Cellular energy monitor
الوصف: Purpose Pulse oximetry is the current standard for detecting drops in arterial blood oxygen saturation (SpO2) associated with obstructive sleep apnea and hypopnea events in polysomnographic (PSG) testing. However, cellular energy monitoring (CE monitoring), a measure related to cellular hypoxia in the skin, is likely to be more responsive to inadequate breathing during sleep because during hypoxic challenge, such as occurs during apneic events, regulatory mechanisms restrict blood flow to the skin to preferentially maintain SpO2 for more vital organs. We carried out initial proof of concept testing to determine if CE monitoring has promise for being more responsive to hypoxic challenge occurring during sleep-disordered breathing (SDB) than pulse oximetry. Methods We assessed both CE monitoring and pulse oximetry in a series of conditions which affect oxygen supply: (1) breathing nitrogen or 100% oxygen, (2) physical exertion, and (3) studying a night of sleep in an individual known to be a loud snorer. We also present the results of a preliminary study comparing CE monitoring to pulse oximetry in eight individuals undergoing standard clinical overnight polysomnography for suspected SDB. Results CE monitoring is responsive to changes in cellular oxygen supply to the skin and detects hypoxia during SDB events that is not detected by pulse oximetry. Conclusion CE monitoring is a promising tool for identifying pathology at the mild end of the SDB spectrum.
وصف الملف: application/pdf
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d85d4a0a3e45488b3b45840597fadfd2
https://escholarship.org/uc/item/7wd6261j
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....d85d4a0a3e45488b3b45840597fadfd2
قاعدة البيانات: OpenAIRE
ResultId 1
Header edsair
OpenAIRE
edsair.doi.dedup.....d85d4a0a3e45488b3b45840597fadfd2
845
3

unknown
844.762634277344
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsair&AN=edsair.doi.dedup.....d85d4a0a3e45488b3b45840597fadfd2&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d85d4a0a3e45488b3b45840597fadfd2# [Name] => EDS - OpenAIRE [Category] => fullText [Text] => View record in OpenAIRE [MouseOverText] => View record in OpenAIRE ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Is cellular energy monitoring more responsive to hypoxia than pulse oximetry? )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Liza+H%2E+Ashbrook%22">Liza H. Ashbrook</searchLink><br /><searchLink fieldCode="AR" term="%22Aric+A%2E+Prather%22">Aric A. Prather</searchLink><br /><searchLink fieldCode="AR" term="%22Andrew+D%2E+Krystal%22">Andrew D. Krystal</searchLink><br /><searchLink fieldCode="AR" term="%22Guy+M%2E+Hatch%22">Guy M. Hatch</searchLink> )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => Sleep & breathing = Schlaf & Atmung, vol 24, iss 4<br />Sleep & Breathing = Schlaf & Atmung )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => eScholarship, University of California, 2020. )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2020 )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Adult%22">Adult</searchLink><br /><searchLink fieldCode="DE" term="%22Male%22">Male</searchLink><br /><searchLink fieldCode="DE" term="%22medicine%2Emedical%5Fspecialty%22">medicine.medical_specialty</searchLink><br /><searchLink fieldCode="DE" term="%22Clinical+Sciences%22">Clinical Sciences</searchLink><br /><searchLink fieldCode="DE" term="%22Respiratory+System%22">Respiratory System</searchLink><br /><searchLink fieldCode="DE" term="%22Pilot+Projects%22">Pilot Projects</searchLink><br /><searchLink fieldCode="DE" term="%22Polysomnography%22">Polysomnography</searchLink><br /><searchLink fieldCode="DE" term="%22Primary+snoring%22">Primary snoring</searchLink><br /><searchLink fieldCode="DE" term="%2203+medical+and+health+sciences%22">03 medical and health sciences</searchLink><br /><searchLink fieldCode="DE" term="%22Wearable+Electronic+Devices%22">Wearable Electronic Devices</searchLink><br /><searchLink fieldCode="DE" term="%220302+clinical+medicine%22">0302 clinical medicine</searchLink><br /><searchLink fieldCode="DE" term="%22Sleep+Apnea+Syndromes%22">Sleep Apnea Syndromes</searchLink><br /><searchLink fieldCode="DE" term="%22Internal+medicine%22">Internal medicine</searchLink><br /><searchLink fieldCode="DE" term="%22medicine%22">medicine</searchLink><br /><searchLink fieldCode="DE" term="%22Humans%22">Humans</searchLink><br /><searchLink fieldCode="DE" term="%22Cellular+hypoxia%22">Cellular hypoxia</searchLink><br /><searchLink fieldCode="DE" term="%22Psychology%22">Psychology</searchLink><br /><searchLink fieldCode="DE" term="%22Exertion%22">Exertion</searchLink><br /><searchLink fieldCode="DE" term="%22Oximetry%22">Oximetry</searchLink><br /><searchLink fieldCode="DE" term="%22Hypoxia%22">Hypoxia</searchLink><br /><searchLink fieldCode="DE" term="%22Aged%22">Aged</searchLink><br /><searchLink fieldCode="DE" term="%22Monitoring%2C+Physiologic%22">Monitoring, Physiologic</searchLink><br /><searchLink fieldCode="DE" term="%22medicine%2Ediagnostic%5Ftest%22">medicine.diagnostic_test</searchLink><br /><searchLink fieldCode="DE" term="%22business%2Eindustry%22">business.industry</searchLink><br /><searchLink fieldCode="DE" term="%22Sleep+disordered+breathing%22">Sleep disordered breathing</searchLink><br /><searchLink fieldCode="DE" term="%22Sleep+Breathing+Physiology+and+Disorders+•+Original+Article%22">Sleep Breathing Physiology and Disorders • Original Article</searchLink><br /><searchLink fieldCode="DE" term="%22Blood+flow%22">Blood flow</searchLink><br /><searchLink fieldCode="DE" term="%22Cellular+hyperoxia%22">Cellular hyperoxia</searchLink><br /><searchLink fieldCode="DE" term="%22Hypoxia+%28medical%29%22">Hypoxia (medical)</searchLink><br /><searchLink fieldCode="DE" term="%22Middle+Aged%22">Middle Aged</searchLink><br /><searchLink fieldCode="DE" term="%22medicine%2Edisease%22">medicine.disease</searchLink><br /><searchLink fieldCode="DE" term="%22Obstructive+sleep+apnea%22">Obstructive sleep apnea</searchLink><br /><searchLink fieldCode="DE" term="%22Pulse+oximetry%22">Pulse oximetry</searchLink><br /><searchLink fieldCode="DE" term="%22030228+respiratory+system%22">030228 respiratory system</searchLink><br /><searchLink fieldCode="DE" term="%22Otorhinolaryngology%22">Otorhinolaryngology</searchLink><br /><searchLink fieldCode="DE" term="%22Cardiology%22">Cardiology</searchLink><br /><searchLink fieldCode="DE" term="%22Arterial+blood%22">Arterial blood</searchLink><br /><searchLink fieldCode="DE" term="%22Female%22">Female</searchLink><br /><searchLink fieldCode="DE" term="%22Neurology+%28clinical%29%22">Neurology (clinical)</searchLink><br /><searchLink fieldCode="DE" term="%22medicine%2Esymptom%22">medicine.symptom</searchLink><br /><searchLink fieldCode="DE" term="%22business%22">business</searchLink><br /><searchLink fieldCode="DE" term="%22Energy+Metabolism%22">Energy Metabolism</searchLink><br /><searchLink fieldCode="DE" term="%22Hypopnea%22">Hypopnea</searchLink><br /><searchLink fieldCode="DE" term="%22030217+neurology+%26+neurosurgery%22">030217 neurology & neurosurgery</searchLink><br /><searchLink fieldCode="DE" term="%22Cellular+energy+monitor%22">Cellular energy monitor</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => Purpose Pulse oximetry is the current standard for detecting drops in arterial blood oxygen saturation (SpO2) associated with obstructive sleep apnea and hypopnea events in polysomnographic (PSG) testing. However, cellular energy monitoring (CE monitoring), a measure related to cellular hypoxia in the skin, is likely to be more responsive to inadequate breathing during sleep because during hypoxic challenge, such as occurs during apneic events, regulatory mechanisms restrict blood flow to the skin to preferentially maintain SpO2 for more vital organs. We carried out initial proof of concept testing to determine if CE monitoring has promise for being more responsive to hypoxic challenge occurring during sleep-disordered breathing (SDB) than pulse oximetry. Methods We assessed both CE monitoring and pulse oximetry in a series of conditions which affect oxygen supply: (1) breathing nitrogen or 100% oxygen, (2) physical exertion, and (3) studying a night of sleep in an individual known to be a loud snorer. We also present the results of a preliminary study comparing CE monitoring to pulse oximetry in eight individuals undergoing standard clinical overnight polysomnography for suspected SDB. Results CE monitoring is responsive to changes in cellular oxygen supply to the skin and detects hypoxia during SDB events that is not detected by pulse oximetry. Conclusion CE monitoring is a promising tool for identifying pathology at the mild end of the SDB spectrum. )
Array ( [Name] => Format [Label] => File Description [Group] => SrcInfo [Data] => application/pdf )
Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d85d4a0a3e45488b3b45840597fadfd2" linkWindow="_blank">https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d85d4a0a3e45488b3b45840597fadfd2</link><br /><link linkTarget="URL" linkTerm="https://escholarship.org/uc/item/7wd6261j" linkWindow="_blank">https://escholarship.org/uc/item/7wd6261j</link> )
Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => OPEN )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsair.doi.dedup.....d85d4a0a3e45488b3b45840597fadfd2 )
RecordInfo Array ( [BibEntity] => Array ( [Languages] => Array ( [0] => Array ( [Text] => Undetermined ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Adult [Type] => general ) [1] => Array ( [SubjectFull] => Male [Type] => general ) [2] => Array ( [SubjectFull] => medicine.medical_specialty [Type] => general ) [3] => Array ( [SubjectFull] => Clinical Sciences [Type] => general ) [4] => Array ( [SubjectFull] => Respiratory System [Type] => general ) [5] => Array ( [SubjectFull] => Pilot Projects [Type] => general ) [6] => Array ( [SubjectFull] => Polysomnography [Type] => general ) [7] => Array ( [SubjectFull] => Primary snoring [Type] => general ) [8] => Array ( [SubjectFull] => 03 medical and health sciences [Type] => general ) [9] => Array ( [SubjectFull] => Wearable Electronic Devices [Type] => general ) [10] => Array ( [SubjectFull] => 0302 clinical medicine [Type] => general ) [11] => Array ( [SubjectFull] => Sleep Apnea Syndromes [Type] => general ) [12] => Array ( [SubjectFull] => Internal medicine [Type] => general ) [13] => Array ( [SubjectFull] => medicine [Type] => general ) [14] => Array ( [SubjectFull] => Humans [Type] => general ) [15] => Array ( [SubjectFull] => Cellular hypoxia [Type] => general ) [16] => Array ( [SubjectFull] => Psychology [Type] => general ) [17] => Array ( [SubjectFull] => Exertion [Type] => general ) [18] => Array ( [SubjectFull] => Oximetry [Type] => general ) [19] => Array ( [SubjectFull] => Hypoxia [Type] => general ) [20] => Array ( [SubjectFull] => Aged [Type] => general ) [21] => Array ( [SubjectFull] => Monitoring, Physiologic [Type] => general ) [22] => Array ( [SubjectFull] => medicine.diagnostic_test [Type] => general ) [23] => Array ( [SubjectFull] => business.industry [Type] => general ) [24] => Array ( [SubjectFull] => Sleep disordered breathing [Type] => general ) [25] => Array ( [SubjectFull] => Sleep Breathing Physiology and Disorders • Original Article [Type] => general ) [26] => Array ( [SubjectFull] => Blood flow [Type] => general ) [27] => Array ( [SubjectFull] => Cellular hyperoxia [Type] => general ) [28] => Array ( [SubjectFull] => Hypoxia (medical) [Type] => general ) [29] => Array ( [SubjectFull] => Middle Aged [Type] => general ) [30] => Array ( [SubjectFull] => medicine.disease [Type] => general ) [31] => Array ( [SubjectFull] => Obstructive sleep apnea [Type] => general ) [32] => Array ( [SubjectFull] => Pulse oximetry [Type] => general ) [33] => Array ( [SubjectFull] => 030228 respiratory system [Type] => general ) [34] => Array ( [SubjectFull] => Otorhinolaryngology [Type] => general ) [35] => Array ( [SubjectFull] => Cardiology [Type] => general ) [36] => Array ( [SubjectFull] => Arterial blood [Type] => general ) [37] => Array ( [SubjectFull] => Female [Type] => general ) [38] => Array ( [SubjectFull] => Neurology (clinical) [Type] => general ) [39] => Array ( [SubjectFull] => medicine.symptom [Type] => general ) [40] => Array ( [SubjectFull] => business [Type] => general ) [41] => Array ( [SubjectFull] => Energy Metabolism [Type] => general ) [42] => Array ( [SubjectFull] => Hypopnea [Type] => general ) [43] => Array ( [SubjectFull] => 030217 neurology & neurosurgery [Type] => general ) [44] => Array ( [SubjectFull] => Cellular energy monitor [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Is cellular energy monitoring more responsive to hypoxia than pulse oximetry? [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Liza H. Ashbrook ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Aric A. Prather ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Andrew D. Krystal ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Guy M. Hatch ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 12 [Type] => published [Y] => 2020 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-locals [Value] => edsair ) [1] => Array ( [Type] => issn-locals [Value] => edsairFT ) ) ) ) ) ) )
IllustrationInfo