Histologic Comparison of Canine Skin Biopsies Collected Using Monopolar Electrosurgery, CO2Laser, Radiowave Radiosurgery, Skin Biopsy Punch, and Scalpel

التفاصيل البيبلوغرافية
العنوان: Histologic Comparison of Canine Skin Biopsies Collected Using Monopolar Electrosurgery, CO2Laser, Radiowave Radiosurgery, Skin Biopsy Punch, and Scalpel
المؤلفون: Carolyn R. Boyle, William W. Miller, Robert C. Cooper, Edward B. Silverman, R. Read, Ron McLaughlin
المصدر: Veterinary Surgery. 36:50-56
بيانات النشر: Wiley, 2007.
سنة النشر: 2007
مصطلحات موضوعية: medicine.medical_specialty, Electrosurgery, Biopsy, medicine.medical_treatment, Skin biopsy punch, Dermatologic Surgical Procedures, Radiosurgery, Necrosis, Random Allocation, Dogs, Dermis, medicine, Animals, Skin, Wound Healing, Co2 laser, integumentary system, General Veterinary, medicine.diagnostic_test, business.industry, Carbon Dioxide, Surgical Instruments, Monopolar electrosurgery, Surgery, medicine.anatomical_structure, Thermal damage, Laser Therapy, Nuclear medicine, business
الوصف: Objective— To compare the histologic appearance of canine skin biopsies collected by use of a scalpel, skin biopsy punch, monopolar electrosurgery, CO2 laser, and radio wave radiosurgery in fully rectified wave form (RWRS). Study Design— Experimental, randomized design. Animals— Healthy adult grayhounds (n=4). Methods— Skin biopsies were collected using 5 techniques. Cut margins of biopsy specimens and adjacent peripheral skin were evaluated using light microscopy to compare penetration of the dermis by tissue carbonization (char). Results— No char occurred in skin specimens collected by biopsy punch and scalpel. Char penetration occurred in all specimens collected by electrosurgery, CO2 laser, and RWRS. Mean char penetration in skin biopsies collected by RWRS (0.158 mm) was significantly less than for monopolar electrosurgery (0.223 mm) and CO2 laser (0.215 mm). Mean char penetration in adjacent peripheral skin surrounding biopsies collected by RWRS (0.171 mm) was significantly less than monopolar electrosurgery (0.255 mm) but not less than CO2 laser (0.215 mm, P
تدمد: 1532-950X
0161-3499
DOI: 10.1111/j.1532-950x.2007.00234.x
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3e42dbbc3ef372697d5ea9abea7ef8b4
https://doi.org/10.1111/j.1532-950x.2007.00234.x
Rights: CLOSED
رقم الانضمام: edsair.doi.dedup.....3e42dbbc3ef372697d5ea9abea7ef8b4
قاعدة البيانات: OpenAIRE