A novel technique of reimplantation of a radial artery that makes a hairpin turn to reduce the excessive vascular access flow in a dialysis patient

التفاصيل البيبلوغرافية
العنوان: A novel technique of reimplantation of a radial artery that makes a hairpin turn to reduce the excessive vascular access flow in a dialysis patient
المؤلفون: Nishizawa Masato, Kimihiro Igari, Toshifumi Kudo, Sotaro Katsui, Yoshinori Inoue
المصدر: The Journal of Vascular Access
بيانات النشر: SAGE Publications, 2020.
سنة النشر: 2020
مصطلحات موضوعية: medicine.medical_specialty, 030232 urology & nephrology, arterial segment, Arteriovenous fistula, Case Reports, 030204 cardiovascular system & hematology, Anastomosis, 03 medical and health sciences, 0302 clinical medicine, Arteriovenous Shunt, Surgical, Renal Dialysis, Internal medicine, medicine.artery, Medicine, Humans, Radial artery, Brachial artery, Vascular Patency, Aged, arterial end-to-side anastomosis, business.industry, cardiac preload, Vascular surgery, medicine.disease, Ostium, Preload, medicine.anatomical_structure, Treatment Outcome, Nephrology, excessive vascular access flow, Regional Blood Flow, Replantation, Radial Artery, Cardiology, Reimplantation of an artery with a hairpin turn (RAHT), Surgery, Female, business, Artery
الوصف: We report a new technique called “reimplantation of an artery with a hairpin turn (RAHT)” to reduce excessive vascular access flow. A 73-year-old woman on dialysis consulted us for vascular surgery because of an increased cardiac preload. Chest radiography and echocardiography revealed an excessive shunt flow in the brachial artery (flow rate, 2336 mL/min). Vascular echo-Doppler of the left upper limb showed that the radial artery made a hairpin turn at the arteriovenous fistula (diameter, 9 mm). Diameters of the radial artery proximal and distal to the arteriovenous fistula were 5.4 and 3.7 mm, respectively. We ligated and divided the juxta-anastomosis proximal radial artery and subsequently created an end-to-side anastomosis between the proximal radial artery and the distal radial artery. The anastomosis ostium in the distal radial artery (the recipient) was formed with a 4-mm longitudinal and gently curved incision. We performed RAHT so that the small anastomosis between both arteries and the small diameter of the distal radial artery juxta-anastomosis segment could reduce the vascular access flow. The flow rates in the brachial artery were 500 mL/min just after surgery and 560 mL/min at 2 months after surgery. Postoperative chest radiography and echocardiography confirmed a decrease in cardiac preload. We believe that this RAHT technique could be useful as one of the options to reduce the flow in patients who have excessive vascular access flow with a radial artery that makes a hairpin turn.
اللغة: English
تدمد: 1724-6032
1129-7298
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3c9d787d44d4e972fc23af6d81b6a046
http://europepmc.org/articles/PMC8295937
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....3c9d787d44d4e972fc23af6d81b6a046
قاعدة البيانات: OpenAIRE