Residual motion of cortical versus pedicle screw constructs after decompression, interbody fusion and cross-link augmentation

التفاصيل البيبلوغرافية
العنوان: Residual motion of cortical versus pedicle screw constructs after decompression, interbody fusion and cross-link augmentation
المؤلفون: Marco D. Burkhard, Frédéric Cornaz, José Miguel Spirig, Florian Wanivenhaus, Marie-Rosa Fasser, Jonas Widmer, Mazda Farshad
المصدر: European Spine Journal, 32 (4)
بيانات النشر: Springer Science and Business Media LLC, 2023.
سنة النشر: 2023
مصطلحات موضوعية: Cortical screw, Cortical bone trajectory, Cross-link, TLIF, Interbody fusion, Orthopedics and Sports Medicine, Surgery
الوصف: PurposeTo compare the residual range of motion (ROM) of cortical screw (CS) versus pedicle screw (PS) instrumented lumbar segments and the additional effect of transforaminal interbody fusion (TLIF) and cross-link (CL) augmentation.MethodsROM of thirty-five human cadaver lumbar segments in flexion/extension (FE), lateral bending (LB), lateral shear (LS), anterior shear (AS), axial rotation (AR), and axial compression (AC) was recorded. After instrumenting the segments with PS (n = 17) and CS (n = 18), ROM in relation to the uninstrumented segments was evaluated without and with CL augmentation before and after decompression and TLIF.ResultsCS and PS instrumentations both significantly reduced ROM in all loading directions, except AC. In undecompressed segments, a significantly lower relative (and absolute) reduction of motion in LB was found with CS 61% (absolute 3.3 degrees) as compared to PS 71% (4.0 degrees; p = 0.048). FE, AR, AS, LS, and AC values were similar between CS and PS instrumented segments without interbody fusion. After decompression and TLIF insertion, no difference between CS and PS was found in LB and neither in any other loading direction. CL augmentation did not diminish differences in LB between CS and PS in the undecompressed state but led to an additional small AR reduction of 11% (0.15 degrees) in CS and 7% (0.05 degrees) in PS instrumentation.ConclusionSimilar residual motion is found with CS and PS instrumentation, except of slightly, but significantly inferior reduction of ROM in LB with CS. Differences between CS and PS in diminish with TLIF but not with CL augmentation.
European Spine Journal, 32 (4)
ISSN:0940-6719
ISSN:1432-0932
ISSN:001991155
وصف الملف: application/application/pdf
تدمد: 1432-0932
0940-6719
DOI: 10.1007/s00586-023-07596-6
URL الوصول: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::173669036bb323d630cd1e85111a492f
https://doi.org/10.1007/s00586-023-07596-6
Rights: OPEN
رقم الانضمام: edsair.doi.dedup.....173669036bb323d630cd1e85111a492f
قاعدة البيانات: OpenAIRE
الوصف
تدمد:14320932
09406719
DOI:10.1007/s00586-023-07596-6