Design study of reflection time-of-flight mass spectrometer for EBIS charge breeder
العنوان: | Design study of reflection time-of-flight mass spectrometer for EBIS charge breeder |
---|---|
المؤلفون: | Taeksu Shin, Hao-Lin Liu, Young Ho Park, Eun-San Kim, Jungbae Bahng |
المصدر: | International Journal of Mass Spectrometry. 467:116621 |
بيانات النشر: | Elsevier BV, 2021. |
سنة النشر: | 2021 |
مصطلحات موضوعية: | Ion beam, Resolution (mass spectrometry), business.industry, Chemistry, Condensed Matter Physics, Mass spectrometry, Ion source, Ion, Time of flight, Optics, Physics::Accelerator Physics, Microchannel plate detector, Physical and Theoretical Chemistry, business, Instrumentation, Spectroscopy, Beam (structure) |
الوصف: | In this study, a time-of-flight mass spectrometer is developed to analyze the mass-to-charge ratio of ion beams generated from an electron beam ion source (EBIS) at the RAON heavy ion accelerator facility. The time-of-flight mass spectrometer comprises a Bradbury–Nielson gate, steerer, mirror electrode, and microchannel plate detector. The Bradbury–Nielson gate is applied to generate a bunch beam with a 5-ns pulse width at the front end of the time-of-flight system. A double-stage reflector is employed to obtain a beam chromatic correction from the energy spread of the ion beam generated from the EBIS. The design is created through optics simulation using the SIMION code, with 133Cs as the reference ion. Consequently, the charge state of 27+ separated from neighboring states at a maximum voltage of 20 kV is obtained. By utilizing ion sources of Cs1+ (m/z 133) and Rb1+ (m/z 85 and m/z 87) to perform the performance test on the designed TOFMS system, the spectral peak of the ion sources and a relatively high mass resolution are obtained. This paper introduces the development process and test results of the time-of-flight mass spectrometer in detail. |
تدمد: | 1387-3806 |
DOI: | 10.1016/j.ijms.2021.116621 |
URL الوصول: | https://explore.openaire.eu/search/publication?articleId=doi_________::3e9b23dfd3625f5ccdc5b26b08086ba0 https://doi.org/10.1016/j.ijms.2021.116621 |
Rights: | CLOSED |
رقم الانضمام: | edsair.doi...........3e9b23dfd3625f5ccdc5b26b08086ba0 |
قاعدة البيانات: | OpenAIRE |
ResultId |
1 |
---|---|
Header |
edsair OpenAIRE edsair.doi...........3e9b23dfd3625f5ccdc5b26b08086ba0 834 3 unknown 833.651123046875 |
PLink |
https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsair&AN=edsair.doi...........3e9b23dfd3625f5ccdc5b26b08086ba0&custid=s6537998&authtype=sso |
FullText |
Array
(
[Availability] => 0
)
Array ( [0] => Array ( [Url] => https://explore.openaire.eu/search/publication?articleId=doi_________::3e9b23dfd3625f5ccdc5b26b08086ba0# [Name] => EDS - OpenAIRE [Category] => fullText [Text] => View record in OpenAIRE [MouseOverText] => View record in OpenAIRE ) ) |
Items |
Array
(
[Name] => Title
[Label] => Title
[Group] => Ti
[Data] => Design study of reflection time-of-flight mass spectrometer for EBIS charge breeder
)
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Taeksu+Shin%22">Taeksu Shin</searchLink><br /><searchLink fieldCode="AR" term="%22Hao-Lin+Liu%22">Hao-Lin Liu</searchLink><br /><searchLink fieldCode="AR" term="%22Young+Ho+Park%22">Young Ho Park</searchLink><br /><searchLink fieldCode="AR" term="%22Eun-San+Kim%22">Eun-San Kim</searchLink><br /><searchLink fieldCode="AR" term="%22Jungbae+Bahng%22">Jungbae Bahng</searchLink> ) Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => <i>International Journal of Mass Spectrometry</i>. 467:116621 ) Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => Elsevier BV, 2021. ) Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2021 ) Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Ion+beam%22">Ion beam</searchLink><br /><searchLink fieldCode="DE" term="%22Resolution+%28mass+spectrometry%29%22">Resolution (mass spectrometry)</searchLink><br /><searchLink fieldCode="DE" term="%22business%2Eindustry%22">business.industry</searchLink><br /><searchLink fieldCode="DE" term="%22Chemistry%22">Chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22Condensed+Matter+Physics%22">Condensed Matter Physics</searchLink><br /><searchLink fieldCode="DE" term="%22Mass+spectrometry%22">Mass spectrometry</searchLink><br /><searchLink fieldCode="DE" term="%22Ion+source%22">Ion source</searchLink><br /><searchLink fieldCode="DE" term="%22Ion%22">Ion</searchLink><br /><searchLink fieldCode="DE" term="%22Time+of+flight%22">Time of flight</searchLink><br /><searchLink fieldCode="DE" term="%22Optics%22">Optics</searchLink><br /><searchLink fieldCode="DE" term="%22Physics%3A%3AAccelerator+Physics%22">Physics::Accelerator Physics</searchLink><br /><searchLink fieldCode="DE" term="%22Microchannel+plate+detector%22">Microchannel plate detector</searchLink><br /><searchLink fieldCode="DE" term="%22Physical+and+Theoretical+Chemistry%22">Physical and Theoretical Chemistry</searchLink><br /><searchLink fieldCode="DE" term="%22business%22">business</searchLink><br /><searchLink fieldCode="DE" term="%22Instrumentation%22">Instrumentation</searchLink><br /><searchLink fieldCode="DE" term="%22Spectroscopy%22">Spectroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22Beam+%28structure%29%22">Beam (structure)</searchLink> ) Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => In this study, a time-of-flight mass spectrometer is developed to analyze the mass-to-charge ratio of ion beams generated from an electron beam ion source (EBIS) at the RAON heavy ion accelerator facility. The time-of-flight mass spectrometer comprises a Bradbury–Nielson gate, steerer, mirror electrode, and microchannel plate detector. The Bradbury–Nielson gate is applied to generate a bunch beam with a 5-ns pulse width at the front end of the time-of-flight system. A double-stage reflector is employed to obtain a beam chromatic correction from the energy spread of the ion beam generated from the EBIS. The design is created through optics simulation using the SIMION code, with 133Cs as the reference ion. Consequently, the charge state of 27+ separated from neighboring states at a maximum voltage of 20 kV is obtained. By utilizing ion sources of Cs1+ (m/z 133) and Rb1+ (m/z 85 and m/z 87) to perform the performance test on the designed TOFMS system, the spectral peak of the ion sources and a relatively high mass resolution are obtained. This paper introduces the development process and test results of the time-of-flight mass spectrometer in detail. ) Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 1387-3806 ) Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1016/j.ijms.2021.116621 ) Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://explore.openaire.eu/search/publication?articleId=doi_________::3e9b23dfd3625f5ccdc5b26b08086ba0" linkWindow="_blank">https://explore.openaire.eu/search/publication?articleId=doi_________::3e9b23dfd3625f5ccdc5b26b08086ba0</link><br /><link linkTarget="URL" linkTerm="https://doi.org/10.1016/j.ijms.2021.116621" linkWindow="_blank">https://doi.org/10.1016/j.ijms.2021.116621</link> ) Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => CLOSED ) Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsair.doi...........3e9b23dfd3625f5ccdc5b26b08086ba0 ) |
RecordInfo |
Array
(
[BibEntity] => Array
(
[Identifiers] => Array
(
[0] => Array
(
[Type] => doi
[Value] => 10.1016/j.ijms.2021.116621
)
)
[Languages] => Array
(
[0] => Array
(
[Text] => Undetermined
)
)
[PhysicalDescription] => Array
(
[Pagination] => Array
(
[PageCount] => 1
[StartPage] => 116621
)
)
[Subjects] => Array
(
[0] => Array
(
[SubjectFull] => Ion beam
[Type] => general
)
[1] => Array
(
[SubjectFull] => Resolution (mass spectrometry)
[Type] => general
)
[2] => Array
(
[SubjectFull] => business.industry
[Type] => general
)
[3] => Array
(
[SubjectFull] => Chemistry
[Type] => general
)
[4] => Array
(
[SubjectFull] => Condensed Matter Physics
[Type] => general
)
[5] => Array
(
[SubjectFull] => Mass spectrometry
[Type] => general
)
[6] => Array
(
[SubjectFull] => Ion source
[Type] => general
)
[7] => Array
(
[SubjectFull] => Ion
[Type] => general
)
[8] => Array
(
[SubjectFull] => Time of flight
[Type] => general
)
[9] => Array
(
[SubjectFull] => Optics
[Type] => general
)
[10] => Array
(
[SubjectFull] => Physics::Accelerator Physics
[Type] => general
)
[11] => Array
(
[SubjectFull] => Microchannel plate detector
[Type] => general
)
[12] => Array
(
[SubjectFull] => Physical and Theoretical Chemistry
[Type] => general
)
[13] => Array
(
[SubjectFull] => business
[Type] => general
)
[14] => Array
(
[SubjectFull] => Instrumentation
[Type] => general
)
[15] => Array
(
[SubjectFull] => Spectroscopy
[Type] => general
)
[16] => Array
(
[SubjectFull] => Beam (structure)
[Type] => general
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => Design study of reflection time-of-flight mass spectrometer for EBIS charge breeder
[Type] => main
)
)
)
[BibRelationships] => Array
(
[HasContributorRelationships] => Array
(
[0] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Taeksu Shin
)
)
)
[1] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Hao-Lin Liu
)
)
)
[2] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Young Ho Park
)
)
)
[3] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Eun-San Kim
)
)
)
[4] => Array
(
[PersonEntity] => Array
(
[Name] => Array
(
[NameFull] => Jungbae Bahng
)
)
)
)
[IsPartOfRelationships] => Array
(
[0] => Array
(
[BibEntity] => Array
(
[Dates] => Array
(
[0] => Array
(
[D] => 01
[M] => 09
[Type] => published
[Y] => 2021
)
)
[Identifiers] => Array
(
[0] => Array
(
[Type] => issn-print
[Value] => 13873806
)
[1] => Array
(
[Type] => issn-locals
[Value] => edsair
)
)
[Numbering] => Array
(
[0] => Array
(
[Type] => volume
[Value] => 467
)
)
[Titles] => Array
(
[0] => Array
(
[TitleFull] => International Journal of Mass Spectrometry
[Type] => main
)
)
)
)
)
)
)
|
IllustrationInfo |