يعرض 1 - 20 نتائج من 37 نتيجة بحث عن '"surgical templates"', وقت الاستعلام: 0.43s تنقيح النتائج
  1. 1
    Academic Journal
  2. 2
    Academic Journal
  3. 3
    Academic Journal
  4. 4
    Academic Journal
  5. 5
    Academic Journal
  6. 6
    Academic Journal
  7. 7
    Academic Journal
  8. 8
    Academic Journal
  9. 9
    Academic Journal
  10. 10
    Academic Journal
  11. 11
  12. 12
  13. 13
  14. 14
    Academic Journal
  15. 15
    Academic Journal

    المؤلفون: Naziri, E, Schramm, A, Wilde, F

    المصدر: GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW; VOL: 5; DOC15 /20160513/

    Relation: Arisan V, Karabuda ZC, Ozdemir T. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol. 2010 Jan;81(1):43-51. DOI:10.1902/jop.2009.090348; Barnea E, Alt I, Kolerman R, Nissan J. Accuracy of a laboratory-based computer implant guiding system. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 May;109(5):e6-e10. DOI:10.1016/j.tripleo.2010.01.001; Behneke A, Burwinkel M, Behneke N. Factors influencing transfer accuracy of cone beam CT-derived template-based implant placement. Clin Oral Implants Res. 2012 Apr;23(4):416-23. DOI:10.1111/j.1600-0501.2011.02337.x; Behneke A, Burwinkel M, d'Hoedt B, Behneke N. Klinische Prüfung der Reliabilität eines DVT-basiertencomputergestützten Implantatplanungkonzeptes auf der Basis laborseitig erzeugter Schablonen. Z Zahnärztl Impl. 2009;25:339-52.; Behneke A, Burwinkel M, Knierim K, Behneke N. Accuracy assessment of cone beam computed tomography-derived laboratory-based surgical templates on partially edentulous patients. Clin Oral Implants Res. 2012 Feb;23(2):137-43. DOI:10.1111/j.1600-0501.2011.02176.x; Brief J, Edinger D, Hassfeld S, Eggers G. Accuracy of image-guided implantology. Clin Oral Implants Res. 2005 Aug;16(4):495-501. DOI:10.1111/j.1600-0501.2005.01133.x; Dreiseidler T, Neugebauer J, Ritter L, Lingohr T, Rothamel D, Mischkowski RA, Zöller JE. Accuracy of a newly developed integrated system for dental implant planning. Clin Oral Implants Res. 2009 Nov;20(11):1191-9. DOI:10.1111/j.1600-0501.2009.01764.x; Eggers G, Patellis E, Mühling J. Accuracy of template-based dental implant placement. Int J Oral Maxillofac Implants. 2009 May-Jun;24(3):447-54. DOI:10.1111/j.1600-0501.2009.01764.x; Fortin T, Bosson JL, Coudert JL, Isidori M. Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. Int J Oral Maxillofac Implants. 2003 Nov-Dec;18(6):886-93. DOI:10.1016/j.prosdent.2004.03.017; Gellrich NC, Held U, Schoen R, Pailing T, Schramm A, Bormann KH. Alveolar zygomatic buttress: A new donor site for limited preimplant augmentation procedures. J Oral Maxillofac Surg. 2007 Feb;65(2):275-80. DOI:10.1016/j.joms.2005.11.081; Hassfeld S, Brief J, Stein W, Ziegler C, Tilmann R, Raczkowsky J, Krempien R, Mühling J. Navigationsverfahren in der Implantologie- Stand der Technik und Perspektiven. Implantologie. 2000;4:373-90.; Hassfeld S, Brief J, Krempien R, Raczkowsky J, Münchenberg J, Giess H, Meinzer HP, Mende U, Wörn H, Mühling J. Computerunterstützte Mund-, Kiefer- und Gesichtschirurgie [Computer-assisted oral, maxillary and facial surgery]. Radiologe. 2000 Mar;40(3):218-26. DOI:10.1007/s001170050660; Hoffmann J, Westendorff C, Gomez-Roman G, Reinert S. Accuracy of navigation-guided socket drilling before implant installation compared to the conventional free-hand method in a synthetic edentulous lower jaw model. Clin Oral Implants Res. 2005 Oct;16(5):609-14. DOI:10.1111/j.1600-0501.2005.01153.x; Hoffmann J, Westendorff C, Schneider M, Reinert S. Accuracy assessment of image-guided implant surgery: an experimental study. Int J Oral Maxillofac Implants. 2005 May-Jun;20(3):382-6.; Hohlweg-Majert B, Schön R, Schmelzeisen R, Gellrich NC, Schramm A. Navigational maxillofacial surgery using virtual models. World J Surg. 2005 Dec;29(12):1530-8. DOI:10.1007/s00268-005-0091-0; Horwitz J, Zuabi O, Machtei EE. Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study. Clin Oral Implants Res. 2009 Oct;20(10):1156-62. DOI:10.1111/j.1600-0501.2009.01748.x; Jung RE, Schneider D, Ganeles J, Wismeijer D, Zwahlen M, Hämmerle CH, Tahmaseb A. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2009;24 Suppl:92-109.; Kalt G, Gehrke P. Transfer precision of three-dimensional implant planning with CT assisted offline navigation. Int J Comput Dent. 2008;11(3-4):213-25.; Neugebauer J, Stachulla G, Ritter L, Dreiseidler T, Mischkowski RA, Keeve E, Zöller JE. Computer-aided manufacturing technologies for guided implant placement. Expert Rev Med Devices. 2010 Jan;7(1):113-29. DOI:10.1586/erd.09.61; Nickenig HJ, Spiekermann H. CT/DVT-basierte implantatprothetische Führungsschablonen vs. Traditionelle Orientierungsschablonen. Z Zahnärztl Implantol. 2006;4:272-80.; Nickenig HJ, Eitner S. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. J Craniomaxillofac Surg. 2007 Jun-Jul;35(4-5):207-11. DOI:10.1016/j.jcms.2007.02.004; Pettersson A, Kero T, Gillot L, Cannas B, Fäldt J, Söderberg R, Näsström K. Accuracy of CAD/CAM-guided surgical template implant surgery on human cadavers: Part I. J Prosthet Dent. 2010 Jun;103(6):334-42. DOI:10.1016/S0022-3913(10)60072-8; Sarment DP, Sukovic P, Clinthorne N. Accuracy of implant placement with a stereolithographic surgical guide. Int J Oral Maxillofac Implants. 2003 Jul-Aug;18(4):571-7.; Schlieper J. Accuracy of template-based implant placements. Int J Digital Dent News. 2010;4:6-17.; Schmelzeisen R, Schön R, Schramm A, Gellrich NC. Computer-aided procedures in implantology, distraction and cranio-maxillofacial surgery. Ann R Australas Coll Dent Surg. 2002 Oct;16:46-9.; Schramm A, Wilde F. Die computergestützte Gesichtsschädelrekonstruktion [Computer-assisted reconstruction of the facial skeleton]. HNO. 2011 Aug;59(8):800-6. DOI:10.1007/s00106-011-2351-7; Schramm A, Gellrich NC, Schimming R, Schmelzeisen R. Rechnergestützte Insertion von Zygomatikumimplantaten (Brånemark-System) nach ablativer Tumorchirurgie [Computer-assisted insertion of zygomatic implants (Brånemark system) after extensive tumor surgery]. Mund Kiefer Gesichtschir. 2000 Sep;4(5):292-5. DOI:10.1007/s100060000211; Schramm A, Gellrich, NC, Schmelzeisen R. Navigational surgery of the facial skeleton. Berlin, Heidelberg, New York: Springer; 2007.; Schramm A, Gellrich NC, Randelzhofer P, Schneider U, Gläser R, Schmelzeisen R. Use and abuse of navigational surgery in oral implantation. In: Lemke HU, Vannier MW, Inamura K, Farman AG, Doi K, editors. CARS 2000. New York: Elsevier; 2000. p. 923-6.; Schramm A, Gellrich NC. Intraoperative Navigation und computerassistierte Chirurgie. In: Schwenzer N, Ehrenfeld M, editors. Zahn-Mund-Kiefer-Heilkunde/Mund-, Kiefer-, Gesichtschirurgie. Stuttgart, New York: Thieme; 2011. p. 478-99.; Schramm A, Schön R, Rücker M, Barth EL, Zizelmann C, Gellrich NC. Computer assisted oral and maxillofacial reconstruction. Int J Comp Techn (CIT). 2006;14(1):71-7. DOI:10.2498/cit.2006.01.08; Wagner A, Wanschitz F, Birkfellner W, Zauza K, Klug C, Schicho K, Kainberger F, Czerny C, Bergmann H, Ewers R. Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. Clin Oral Implants Res. 2003 Jun;14(3):340-8. DOI:10.1034/j.1600-0501.2003.110812.x; Westendorf S, Naziri E, Eisenmann H, Luthardt RG, Schramm A. 3D techniques in dental implantology. Int J Digital Dent News. 2010;4:32-45.; Widmann G, Bale RJ. Accuracy in computer-aided implant surgery - a review. Int J Oral Maxillofac Implants. 2006 Mar-Apr;21(2):305-13.; http://dx.doi.org/10.3205/iprs000094; http://nbn-resolving.de/urn:nbn:de:0183-iprs0000943; http://www.egms.de/en/journals/iprs/2016-5/iprs000094.shtml

  16. 16
    Academic Journal
  17. 17
  18. 18
  19. 19
    Academic Journal
  20. 20
    Periodical