يعرض 1 - 10 نتائج من 10 نتيجة بحث عن '"coneâ€beam computed tomography"', وقت الاستعلام: 0.59s تنقيح النتائج
  1. 1
    Academic Journal
  2. 2
  3. 3
    Academic Journal

    وصف الملف: application/pdf

    Relation: Taylor, Kyle L.; Evangelista, Karine; Muniz, Luciana; Ruellas, Antônio Carlos De Oliveira; Valladares‐neto, José; McNamara, James; Franchi, Lorenzo; Kim‐berman, Hera; Cevidanes, Lucia Helena Soares (2020). "Threeâ dimensional comparison of the skeletal and dentoalveolar effects of the Herbst and Pendulum appliances followed by fixed appliances: A CBCT study." Orthodontics & Craniofacial Research 23(1): 72-81.; https://hdl.handle.net/2027.42/153549; Orthodontics & Craniofacial Research; Ruellas ACdO, Huanca Ghislanzoni LT, Gomes MR, et al. Comparison and reproducibility of 2 regions of reference for maxillary regional registration with coneâ beam computed tomography. Am J Orthod Dentofacial Orthop. 2016; 149: 533 â 542.; Pancherz H. Treatment of class II malocclusions by jumping the bite with the Herbst appliance. A cephalometric investigation. Am J Orthod. 1979; 76: 423 â 442.; Bussick TJ, McNamara JA Jr. Dentoalveolar and skeletal changes associated with the pendulum appliance. Am J Orthod Dentofac Orthop. 2000; 117: 333 â 343.; Hilgers JJ. The pendulum appliance for class II nonâ compliance therapy. J Clin Orthod. 1992; 26: 706 â 714.; Nelson B, Hansen K, Hägg U. Class II correction in patients treated with class II elastics and with fixed functional appliances: a comparative study. Am J Orthod Dentofacial Orthop. 2000; 118: 142 â 149.; Tomblyn T, Rogers M, Andrews L, et al. Cephalometric study of Class II division 1 patients treated with an extendedâ duration, reinforced, banded Herbst appliance followed by fixed appliances. Am J Orthod Dentofacial Orthop. 2016; 150: 818 â 830.; Caprioglio A, Fontana M, Longoni E, Cozzani M. Longâ term evaluation of the molar movements following Pendulum and fixed appliances. Angle Orthod. 2013; 83: 447 â 454.; Fuziy A, de Almeida RR, Janson G, Angelieri F, Pinzan A. Sagittal, vertical, and transverse changes consequent to maxillary molar distalization with the pendulum appliance. Am J Orthod Dentofac Orthop. 2006; 130: 502 â 510.; Cozza P, Baccetti T, Franchi L, De Toffol L, McNamara JA. Mandibular changes produced by functional appliances in class II malocclusion: a systematic review. Am J Orthod Dentofacial Orthop. 2006; 129 ( 5 ): 599.e1 â 599.e12.; Rogers K, Campbell PM, Tadlock L, Schneiderman E, Buschang PH. Treatment changes of hypoâ and hyperdivergent class II Herbst patients. Angle Orthod. 2018; 88: 3 â 9.; Rabie AB, Zhao Z, Shen G, Hägg EU, Dr O, Robinson W. Osteogenesis in the glenoid fossa in response to mandibular advancement. Am J Orthod Dentofacial Orthop. 2001; 119: 390 â 400.; Baccetti T, Franchi L, Stahl F. Comparison of 2 comprehensive Class II treatment protocols including the bonded Herbst and headgear appliances: a doubleâ blind study of consecutively treated patients at puberty. Am J Orthod Dentofacial Orthop. 2009; 135 ( 6 ): 698.e1 â 698.e10.; Souki BQ, Vilefort P, Oliveira DD, et al. Threeâ dimensional skeletal mandibular changes associated with Herbst appliance treatment. Orthod Craniofac Res. 2017; 20: 111 â 118.; Atresh A, Cevidanes L, Yatabe M, et al. Threeâ dimensional treatment outcomes in class II patients with different vertical facial patterns treated with the Herbst appliance. Am J Orthod Dentofacial Orthop. 2018; 154 ( 2 ): 238 â 248.e1.; Burkhardt DR, McNamara JA Jr, Baccetti T. Maxillary molar distalization or mandibular enhancement: a cephalometric comparison of comprehensive orthodontic treatment including the pendulum and the Herbst appliances. Am J Orthod Dentofac Orthop. 2003; 123: 108 â 116.; McNamara JA Jr, Franchi L. The cervical vertebral maturation method: a userâ s guide. Angle Orthod. 2018; 88: 133 â 143.; Ruellas A, Tonello C, Gomes LR, et al. Common 3â dimensional coordinate system for assessment of directional changes. Am J Orthod Dentofac Orthop. 2016; 149: 645 â 656.; Cevidanes L, Styner MA, Proffit WR. Image analysis and superimposition of 3â dimensional coneâ beam computed tomography models. Am J Orthod Dentofac Orthop. 2006; 129: 611 â 618.; De Oliveira Ruellas AC, Yatabe MS, Souki BQ, et al. 3D mandibular superimposition: comparison of regions of reference for voxelâ based registration. PLoS ONE. 2016; 11: 1 â 13.; Pancherz H, Anehusâ Pancherz M. The headgear effect of the Herbst appliance: a cephalometric longâ term study. Am J Orthod Dentofacial Orthop. 1993; 103: 510 â 520.; Wigal TG, Dischinger T, Martin C, Razmus T, Gunel E, Ngan P. Stability of class II treatment with an edgewise crowned Herbst appliance in the early mixed dentition: Skeletal and dental changes. Am J Orthod Dentofac Orthop. 2011; 140: 210 â 223.; Barnett GA, Higgins DW, Major PW, Floresâ Mir C. Immediate skeletal and dentoalveolar effects of the crownâ or banded type Herbst appliance on class II division 1 malocclusion. Angle Orthod. 2008; 78: 361 â 369.; Lai M, McNamara JA Jr. An evaluation of twoâ phase treatment with the Herbst appliance and preadjusted edgewise therapy. Semin Orthod. 1998; 4: 46 â 58.; Chiu PP, McNamara JA Jr, Franchi L. A comparison of two intraoral molar distalization appliances: distal jet versus pendulum. Am J Orthod Dentofac Orthop. 2005; 128: 353 â 365.; Hansen K, Pancherz H, Hägg U. Longâ term effects of the Herbst appliance in relation to the treatment growth period: a cephalometric study. Eur J Orthod. 1991; 13: 471 â 481.; Martin J, Pancherz H. Mandibular incisor position in relation to amount of bite jumping during Herbst/multibracket appliance treatment: a radiographicâ cephalometric study. Am J Orthod Dentofac Orthop. 2009; 136: 44 â 51.; Oenning AC, Jacobs R, Pauwels R, Straits A, Hedesiu M, Salmon B. Coneâ beam CT in paediatric dentistry: DIMITRA project position statement. Pediatr Radiol. 2018; 48: 308 â 316.

  4. 4
  5. 5
    Academic Journal

    وصف الملف: application/pdf

    Relation: Ravidà, Andrea; Barootchi, Shayan; Tattan, Mustafa; Saleh, Muhammad H. A.; Gargallo‐albiol, Jordi; Wang, Hom‐lay (2018). "Clinical outcomes and cost effectiveness of computerâ guided versus conventional implantâ retained hybrid prostheses: A longâ term retrospective analysis of treatment protocols." Journal of Periodontology 89(9): 1015-1024.; https://hdl.handle.net/2027.42/145504; Journal of Periodontology; Buser D, Halbritter S, Hart C, et al. Early implant placement with simultaneous guided bone regeneration following singleâ tooth extraction in the esthetic zone: 12â month results of a prospective study with 20 consecutive patients. J Periodontol. 2009; 80: 152 â 162.; Cushen SE, Turkyilmaz I. Impact of operator experience on the accuracy of implant placement with stereolithographic surgical templates: an in vitro study. J Prosthet Dent. 2013; 109: 248 â 254.; Laleman I, Bernard L, Vercruyssen M, Jacobs R, Bornstein MM, Quirynen M. Guided Implant Surgery in the Edentulous Maxilla: a Systematic Review. Int J Oral Maxillofac Implants. 2016; 31 ( Suppl ): s103 â 117.; Armitage GC. Periodontal diagnoses and classification of periodontal diseases. Periodontol 2000. 2004; 34: 9 â 21.; Pihlstrom BL, Michalowicz BS, Johnson NW. Periodontal diseases. Lancet. 2005; 366: 1809 â 1820.; Tonetti M. Palmer R, Working Group 2 of the VEWoP. Clinical research in implant dentistry: study design, reporting and outcome measurements: consensus report of Working Group 2 of the VIII European Workshop on Periodontology. J Clin Periodontol. 2012; 39 ( Suppl 12 ): 73 â 80.; Schneider CA, Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 years of image analysis. Nat Methods. 2012; 9: 671 â 675.; Chrcanovic BR, Albrektsson T, Wennerberg A. Reasons for failures of oral implants. J Oral Rehabil. 2014; 41: 443 â 476.; Kalincik T, Butzkueven H. Observational data: understanding the real MS world. Mult Scler. 2016; 22: 1642 â 1648.; Trojano M, Tintore M, Montalban X, et al. Treatment decisions in multiple sclerosis â insights from realâ world observational studies. Nat Rev Neurol. 2017; 13: 105 â 118.; Buser D, Chen ST, Weber HP, Belser UC. Early implant placement following singleâ tooth extraction in the esthetic zone: biologic rationale and surgical procedures. Int J Periodontics Restorative Dent. 2008; 28: 441 â 451.; Monje A, Galindoâ Moreno P, Tozum TF, Suarezâ Lopez del Amo F, Wang HL. Into the Paradigm of Local Factors as Contributors for Periâ implant Disease: short Communication. Int J Oral Maxillofac Implants. 2016; 31: 288 â 292.; Popper HA, Popper MJ, Popper JP. Teeth in a day. The Branemark Novum system. N Y State Dent J. 2003; 69: 24 â 27.; Malo P, Rangert B, Nobre M. Allâ onâ Fourâ immediateâ function concept with Branemark System implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res. 2003; 5 ( Suppl 1 ): 2 â 9.; Krekmanov L, Kahn M, Rangert B, Lindstrom H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants. 2000; 15: 405 â 414.; Cannizzaro G, Leone M, Consolo U, Ferri V, Esposito M. Immediate functional loading of implants placed with flapless surgery versus conventional implants in partially edentulous patients: a 3â year randomized controlled clinical trial. Int J Oral Maxillofac Implants. 2008; 23: 867 â 875.; Esposito M, Grusovin MG, Maghaireh H, Coulthard P, Worthington HV. Interventions for replacing missing teeth: management of soft tissues for dental implants. Cochrane Database Syst Rev. 2007: CD006697.; Balshi SF, Wolfinger GJ, Balshi TJ. Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: a pilot study of 23 patients. Implant Dent. 2008; 17: 128 â 135.; Malo P, de Araujo Nobre M, Lopes A. The use of computerâ guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean followâ up period of thirteen months. J Prosthet Dent. 2007; 97: S26 â 34.; Gillot L, Noharet R, Cannas B. Guided surgery and presurgical prosthesis: preliminary results of 33 fully edentulous maxillae treated in accordance with the NobelGuide protocol. Clin Implant Dent Relat Res. 2010; 12 ( Suppl 1 ): e104 â 113.; Marra R, Acocella A, Rispoli A, Sacco R, Ganz SD, Blasi A. Fullâ mouth rehabilitation with immediate loading of implants inserted with computerâ guided flapâ less surgery: a 3â year multicenter clinical evaluation with oral health impact profile. Implant Dent. 2013; 22: 444 â 452.; Kappert PF, Kelly JR. Cyclic fatigue testing of denture teeth for bulk fracture. Dent Mater. 2013; 29: 1012 â 1019.; Pomares C. A retrospective study of edentulous patients rehabilitated according to the â allâ onâ fourâ or the â allâ onâ sixâ immediate function concept using flapless computerâ guided implant surgery. Eur J Oral Implantol. 2010; 3: 155 â 163.; Vercruyssen M, Hultin M, Van Assche N, Svensson K, Naert I, Quirynen M. Guided surgery: accuracy and efficacy. Periodontol 2000. 2014; 66: 228 â 246.; Van de Wiele G, Teughels W, Vercruyssen M, Coucke W, Temmerman A, Quirynen M. The accuracy of guided surgery via mucosaâ supported stereolithographic surgical templates in the hands of surgeons with little experience. Clin Oral Implants Res. 2015; 26: 1489 â 1494.; Meloni SM, De Riu G, Pisano M, Cattina G, Tullio A. Implant treatment software planning and guided flapless surgery with immediate provisional prosthesis delivery in the fully edentulous maxilla. A retrospective analysis of 15 consecutively treated patients. Eur J Oral Implant. 2010; 3: 245 â 251.; Merli M, Bernardelli F, Esposito M. Computerâ guided flapless placement of immediately loaded dental implants in the edentulous maxilla: a pilot prospective case series. Eur J Oral Implant. 2008; 1: 61 â 69.; Goodacre CJ, Naylor WP. Single implant and crown versus fixed partial denture: a costâ benefit, patientâ centred analysis. Eur J Oral Implant. 2016; 9 ( Suppl 1 ): S59 â 68.; Tarnow DP. Increasing Prevalence of Periâ implantitis: how Will We Manage. J Dent Res. 2016; 95: 7 â 8.; Nickenig HJ, Eitner S. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates. J Craniomaxillofac Surg. 2007; 35: 207 â 211.; Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998; 106: 721 â 764.; Vercruyssen M, Fortin T, Widmann G, Jacobs R, Quirynen M. Different techniques of static/dynamic guided implant surgery: modalities and indications. Periodontol 2000. 2014; 66: 214 â 227.; Van Assche N, Vercruyssen M, Coucke W, Teughels W, Jacobs R, Quirynen M. Accuracy of computerâ aided implant placement. Clin Oral Implants Res. 2012; 23 ( Suppl 6 ): 112 â 123.; Tahmaseb A, Wismeijer D, Coucke W, Derksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014; 29 ( Suppl ): 25 â 42.; D’Haese J, Ackhurst J, Wismeijer D, De Bruyn H, Tahmaseb A. Current state of the art of computerâ guided implant surgery. Periodontol 2000. 2017; 73: 121 â 133.; van Steenberghe D, Glauser R, Blomback U, et al. A computed tomographic scanâ derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study. Clin Implant Dent Relat Res. 2005; 7 ( Suppl 1 ): S111 â 120.; Krekmanov L. Placement of posterior mandibular and maxillary implants in patients with severe bone deficiency: a clinical report of procedure. Int J Oral Maxillofac Implants. 2000; 15: 722 â 730.; Vasak C, Kohal RJ, Lettner S, Rohner D, Zechner W. Clinical and radiological evaluation of a templateâ guided (NobelGuide) treatment concept. Clin Oral Implants Res. 2014; 25: 116 â 123.; Lopes A, Malo P, de Araujo Nobre M, Sanchezâ Fernandez E, Gravito I. The NobelGuide(R) Allâ onâ 4(R) Treatment Concept for Rehabilitation of Edentulous Jaws: a Retrospective Report on the 7â Years Clinical and 5â Years Radiographic Outcomes. Clin Implant Dent Relat Res. 2017; 19: 233 â 244.; Van Assche N, van Steenberghe D, Guerrero ME, et al. Accuracy of implant placement based on preâ surgical planning of threeâ dimensional coneâ beam images: a pilot study. J Clin Periodontol. 2007; 34: 816 â 821.; Pettersson A, Kero T, Gillot L, et al. Accuracy of CAD/CAMâ guided surgical template implant surgery on human cadavers: part I. J Prosthet Dent. 2010; 103: 334 â 342.; Pettersson A, Kero T, Soderberg R, Nasstrom K. Accuracy of virtually planned and CAD/CAMâ guided implant surgery on plastic models. J Prosthet Dent. 2014; 112: 1472 â 1478.

  6. 6
    Academic Journal

    وصف الملف: application/pdf

    Relation: Chan, Hsun‐liang; Wang, Hom‐lay; Fowlkes, Jeffery Brian; Giannobile, William V.; Kripfgans, Oliver D. (2017). "Nonâ ionizing realâ time ultrasonography in implant and oral surgery: A feasibility study." Clinical Oral Implants Research 28(3): 341-347.; https://hdl.handle.net/2027.42/136518; Clinical Oral Implants Research; Loubele, M., Guerrero, M.E., Jacobs, R., Suetens, P. & van Steenberghe, D. ( 2007 ) A comparison of jaw dimensional and quality assessments of bone characteristics with coneâ beam ct, spiral tomography, and multiâ slice spiral ct. International Journal of Oral and Maxillofacial Implants 22: 446 â 454.; Friedrich, R.E., Zustin, J. & Scheuer, H.A. ( 2010 ) Adenomatoid odontogenic tumour of the mandible. Anticancer Research 30: 1787 â 1792.; Fu, J.H., Hasso, D.G., Yeh, C.Y., Leong, D.J., Chan, H.L. & Wang, H.L. ( 2011 ) The accuracy of identifying the greater palatine neurovascular bundle: a cadaver study. Journal of Periodontology 82: 1000 â 1006.; Fu, J.H., Yeh, C.Y., Chan, H.L., Tatarakis, N., Leong, D.J. & Wang, H.L. ( 2010 ) Tissue biotype and its relation to the underlying bone morphology. Journal of Periodontology 81: 569 â 574.; Gonzalezâ Martin, O., Oteo, C., Ortega, R., Alandez, J., Sanz, M. & Veltri, M. ( 2015 ) Evaluation of periâ implant buccal bone by computed tomography: an experimental study. Clinical Oral Implants Research, doi:10.1111/clr.12663.; Gundappa, M., Ng, S.Y. & Whaites, E.J. ( 2006 ) Comparison of ultrasound, digital and conventional radiography in differentiating periapical lesions. Dentomaxillofacial Radiology 35: 326 â 333.; Hadlock, F.P., Harrist, R.B. & Martinezâ Poyer, J. ( 1991 ) In utero analysis of fetal growth: a sonographic weight standard. Radiology 181: 129 â 133.; Horner, K., Islam, M., Flygare, L., Tsiklakis, K. & Whaites, E. ( 2009 ) Basic principles for use of dental cone beam computed tomography: consensus guidelines of the european academy of dental and maxillofacial radiology. Dentomaxillofac Radiology 38: 187 â 195.; Hughes, D.A., Girkin, J.M., Poland, S., Longbottom, C., Button, T.W., Elgoyhen, J., Hughes, H., Meggs, C. & Cochran, S. ( 2009 ) Investigation of dental samples using a 35mhz focussed ultrasound piezocomposite transducer. Ultrasonics 49: 212 â 218.; Kan, J.Y., Morimoto, T., Rungcharassaeng, K., Roe, P. & Smith, D.H. ( 2010 ) Gingival biotype assessment in the esthetic zone: visual versus direct measurement. International Journal of Periodontics and Restorative Dentistry 30: 237 â 243.; Kuhl, S., Zurcher, S., Zitzmann, N.U., Filippi, A., Payer, M. & Dagassanâ Berndt, D. ( 2015 ) Detection of periâ implant bone defects with different radiographic techniques â a human cadaver study. Clinical Oral Implants Research doi:10.1111/clr.12619.; Lin, G.H., Chan, H.L. & Wang, H.L. ( 2014 ) Effects of currently available surgical and restorative interventions on reducing midfacial mucosal recession of immediately placed singleâ tooth implants: a systematic review. Journal of Periodontology 85: 92 â 102.; Ludlow, J.B., Laster, W.S., See, M., Bailey, L.J. & Hershey, H.G. ( 2007 ) Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology 103: 534 â 542.; Machtei, E.E., Zigdon, H., Levin, L. & Peled, M. ( 2010 ) Novel ultrasonic device to measure the distance from the bottom of the osteotome to various anatomic landmarks. Journal of Periodontology 81: 1051 â 1055.; Mahmoud, A.M., Ngan, P., Crout, R. & Mukdadi, O.M. ( 2010 ) Highâ resolution 3d ultrasound jawbone surface imaging for diagnosis of periodontal bony defects: an in vitro study. Annual of Biomedical Engineering 38: 3409 â 3422.; Muller, H.P., Barrieshiâ Nusair, K.M. & Kononen, E. ( 2007 ) Repeatability of ultrasonic determination of gingival thickness. Clinical Oral Investigation 11: 439 â 442.; Muller, H.P. & Kononen, E. ( 2005 ) Variance components of gingival thickness. Journal of Periodontal Research 40: 239 â 244.; Neal, J.M., Brull, R., Chan, V.W., Grant, S.A., Horn, J.L., Liu, S.S., McCartney, C.J., Narouze, S.N., Perlas, A., Salinas, F.V., Sites, B.D. & Tsui, B.C. ( 2010 ) The asra evidenceâ based medicine assessment of ultrasoundâ guided regional anesthesia and pain medicine: executive summary. Regional Anesthesia and Pain Medicine 35: S1 â S9.; Pallagatti, S., Sheikh, S., Puri, N., Mittal, A. & Singh, B. ( 2012 ) To evaluate the efficacy of ultrasonography compared to clinical diagnosis, radiography and histopathological findings in the diagnosis of maxillofacial swellings. European Journal of Radiology 81: 1821 â 1827.; Rajendran, N. & Sundaresan, B. ( 2007 ) Efficacy of ultrasound and color power doppler as a monitoring tool in the healing of endodontic periapical lesions. Journal of Endodontics 33: 181 â 186.; Slak, B., Ambroziak, A., Strumban, E. & Maev, R.G. ( 2011 ) Enamel thickness measurement with a high frequency ultrasonic transducerâ based handâ held probe for potential application in the dental veneer placing procedure. Acta of Bioengineering and Biomechanics 13: 65 â 70.; Tsiolis, F.I., Needleman, I.G. & Griffiths, G.S. ( 2003 ) Periodontal ultrasonography. Journal of Clinical Periodontology 30: 849 â 854.; Wakasugiâ Sato, N., Kodama, M., Matsuo, K., Yamamoto, N., Oda, M., Ishikawa, A., Tanaka, T., Seta, Y., Habu, M., Kokuryo, S., Ichimiya, H., Miyamoto, I., Kito, S., Matsumotoâ Takeda, S., Wakasugi, T., Yamashita, Y., Yoshioka, I., Takahashi, T., Tominaga, K. & Morimoto, Y. ( 2010 ) Advanced clinical usefulness of ultrasonography for diseases in oral and maxillofacial regions. International Journal of Dentistry 2010: 639382.; Yamamoto, N., Yamashita, Y., Tanaka, T., Ishikawa, A., Kito, S., Wakasugiâ Sato, N., Matsumotoâ Takeda, S., Oda, M., Miyamoto, I., Yamauchi, K., Shiiba, S., Seta, Y., Matsuo, K., Koga, H., Takahashi, T. & Morimoto, Y. ( 2011 ) Diagnostic significance of characteristic findings on ultrasonography for the stitch abscess after surgery in patients with oral squamous cell carcinoma. Oral Oncology 47: 163 â 169.; Aggarwal, V., Logani, A. & Shah, N. ( 2008 ) The evaluation of computed tomography scans and ultrasounds in the differential diagnosis of periapical lesions. Journal of Endodontics 34: 1312 â 1315.; Backhaus, M., Burmester, G.R., Gerber, T., Grassi, W., Machold, K.P., Swen, W.A., Wakefield, R.J. & Manger, B. ( 2001 ) Guidelines for musculoskeletal ultrasound in rheumatology. Annuals of Rheumatic Disease 60: 641 â 649.; Barratt, D.C., Penney, G.P., Chan, C.S., Slomczykowski, M., Carter, T.J., Edwards, P.J. & Hawkes, D.J. ( 2006 ) Selfâ calibrating 3dâ ultrasoundâ based bone registration for minimally invasive orthopedic surgery. IEEE Transactions on Medical Imaging 25: 312 â 323.; Blankstein, A. ( 2011 ) Ultrasound in the diagnosis of clinical orthopedics: The orthopedic stethoscope. World Journal of Orthopedics 2: 13 â 24.; Bozkurt, F.O., Tagtekin, D.A., Hayran, O., Stookey, G.K. & Yanikoglu, F.C. ( 2005 ) Accuracy of ultrasound measurement of progressive change in occlusal enamel thickness. Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology 99: 101 â 105.; Cardinal, E., Bureau, N.J., Aubin, B. & Chhem, R.K. ( 2001 ) Role of ultrasound in musculoskeletal infections. Radiologic Clinics of North America 39: 191 â 201.; Chan, H.L., Garaicoaâ Pazmino, C., Suarez, F., Monje, A., Benavides, E., Oh, T.J. & Wang, H.L. ( 2014 ) Incidence of implant buccal plate fenestration in the esthetic zone: a cone beam computed tomography study. International Journal of Oral Maxillofacial Implants 29: 171 â 177.; Chan, H.L., Leong, D.J., Fu, J.H., Yeh, C.Y., Tatarakis, N. & Wang, H.L. ( 2010a ) The significance of the lingual nerve during periodontal/implant surgery. Journal of Periodontology 81: 372 â 377.; Chan, H.L., Misch, K. & Wang, H.L. ( 2010b ) Dental imaging in implant treatment planning. Implant Dentistry 19: 288 â 298.; Chandak, R., Degwekar, S., Bhowte, R.R., Motwani, M., Banode, P., Chandak, M. & Rawlani, S. ( 2011 ) An evaluation of efficacy of ultrasonography in the diagnosis of head and neck swellings. Dentomaxillofacial Radiology 40: 213 â 221.; Chao, Y.C., Chang, P.C., Fu, J.H., Wang, H.L. & Chan, H.L. ( 2015 ) Surgical site assessment for soft tissue management in ridge augmentation procedures. International Journal of Periodontics and Restorative Dentistry 35: e75 â e83.; Chifor, R., Hedesiu, M., Bolfa, P., Catoi, C., Crisan, M., Serbanescu, A., Badea, A.F., Moga, I. & Badea, M.E. ( 2011 ) The evaluation of 20 mhz ultrasonography, computed tomography scans as compared to direct microscopy for periodontal system assessment. Medical Ultrasonography 13: 120 â 126.; Cotti, E., Campisi, G., Ambu, R. & Dettori, C. ( 2003 ) Ultrasound realâ time imaging in the differential diagnosis of periapical lesions. International Endodontic Journal 36: 556 â 563.; Cotti, E., Campisi, G., Garau, V. & Puddu, G. ( 2002 ) A new technique for the study of periapical bone lesions: ultrasound real time imaging. International Endodontic Journal 35: 148 â 152.; Culjat, M.O., Choi, M., Singh, R.S., Grundfest, W.S., Brown, E.R. & White, S.N. ( 2008 ) Ultrasound detection of submerged dental implants through soft tissue in a porcine model. Journal of Prosthetic Dentistry 99: 218 â 224.; Culjat, M., Singh, R.S., Yoon, D.C. & Brown, E.R. ( 2003 ) Imaging of human tooth enamel using ultrasound. IEEE Transactions on Medical Imaging 22: 526 â 529.

  7. 7
    Academic Journal

    المساهمون: Graduate Periodontics, School of Dentistry, University of Michigan, Ann Arbor, MI., Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan.

    وصف الملف: application/pdf

    Relation: Chan, Hsun‐liang; Benavides, Erika; Yeh, Chu‐yuan; Fu, Jia‐hui; Rudek, Ivan E.; Wang, Hom‐lay (2011). "Risk Assessment of Lingual Plate Perforation in Posterior Mandibular Region: A Virtual Implant Placement Study Using Coneâ Beam Computed Tomography." Journal of Periodontology 82(1): 129-135.; https://hdl.handle.net/2027.42/141229; Journal of Periodontology; Gastaldo JF, Cury PR, Sendyk WR. Effect of the vertical and horizontal distances between adjacent implants and between a tooth and an implant on the incidence of interproximal papilla. J Periodontol 2004; 75: 1242 â 1246.; Romeo E, Lops D, Rossi A, Storelli S, Rozza R, Chiapasco M. Surgical and prosthetic management of interproximal region with singleâ implant restorations: 1â year prospective study. J Periodontol 2008; 79: 1048 â 1055.; Pearson K. Determination of the coefficient of correlation. Science 1909; 30: 23 â 25.; Van Assche N, van Steenberghe D, Guerrero ME, et al. Accuracy of implant placement based on preâ surgical planning of threeâ dimensional coneâ beam images: A pilot study. J Clin Periodontol 2007; 34: 816 â 821.; Ganz SD. Computerâ aided design/computerâ aided manufacturing applications using CT and cone beam CT scanning technology. Dent Clin North Am 2008; 52: 777 â 808, vii.; Schneider D, Marquardt P, Zwahlen M, Jung RE. A systematic review on the accuracy and the clinical outcome of computerâ guided templateâ based implant dentistry. Clin Oral Implants Res 2009; 20 ( Suppl. 4 ): 73 â 86.; Berberi A, Le Breton G, Mani J, Woimant H, Nasseh I. Lingual paresthesia following surgical placement of implants: Report of a case. Int J Oral Maxillofac Implants 1993; 8: 580 â 582.; Sammartino G, Marenzi G, Citarella R, Ciccarelli R, Wang HL. Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded fixture. J Periodontol 2008; 79: 1735 â 1744.; Chiapasco M, Abati S, Romeo E, Vogel G. Clinical outcome of autogenous bone blocks or guided bone regeneration with eâ PTFE membranes for the reconstruction of narrow edentulous ridges. Clin Oral Implants Res 1999; 10: 278 â 288.; Tarnow DP, Cho SC, Wallace SS. The effect of interâ implant distance on the height of interâ implant bone crest. J Periodontol 2000; 71: 546 â 549.; Greenstein G, Cavallaro J, Tarnow D. Practical application of anatomy for the dental implant surgeon. J Periodontol 2008; 79: 1833 â 1846.; Adell R, Lekholm U, Rockler B, BrÃ¥nemark PI. A 15â year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981; 10: 387 â 416.; Scheller H, Urgell JP, Kultje C, et al. A 5â year multicenter study on implantâ supported single crown restorations. Int J Oral Maxillofac Implants 1998; 13: 212 â 218.; Becker CM, Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000; 83: 248 â 251.; Misch CE, Bidez MW. Implantâ protected occlusion: A biomechanical rationale. Compendium 1994; 15: 1330, 1332, 1334 passim; quiz 1344.; Reilly DT, Burstein AH. The elastic and ultimate properties of compact bone tissue. J Biomech 1975; 8: 393 â 405.; Lin CL, Wang JC, Ramp LC, Liu PR. Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loading. Int J Oral Maxillofac Implants 2008; 23: 57 â 64.; Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H. Mandible size and morphology determined with CT on a premise of dental implant operation. Surg Radiol Anat 2010; 32: 343 â 349.; White SC. Coneâ beam imaging in dentistry. Health Phys 2008; 95: 628 â 637.; Quirynen M, Mraiwa N, van Steenberghe D, Jacobs R. Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas. Clin Oral Implants Res 2003; 14: 280 â 285.; Tepper G, Hofschneider UB, Gahleitner A, Ulm C. Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complications during implant surgery. Int J Oral Maxillofac Implants 2001; 16: 68 â 72.; Watanabe H, Mohammad Abdul M, Kurabayashi T, Aoki H. Mandible size and morphology determined with CT on a premise of dental implant operation. Surg Radiol Anat 2010; 32 ( 4 ): 343 â 349.; Parnia F, Fard EM, Mahboub F, Hafezeqoran A, Gavgani FE. Tomographic volume evaluation of submandibular fossa in patients requiring dental implants. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e32 â e36.; Draenert FG, Coppenrath E, Herzog P, Müller S, Muellerâ Lisse UG. Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4â row multidetector CT. Dentomaxillofac Radiol 2007; 36: 198 â 203.; Scarfe WC, Farman AG. What is coneâ beam CT and how does it work? Dent Clin North Am 2008; 52: 707 â 730.; Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCTâ NewTom). Dentomaxillofac Radiol 2004; 33: 291 â 294.; Ito K, Gomi Y, Sato S, Arai Y, Shinoda K. Clinical application of a new compact CT system to assess 3â D images for the preoperative treatment planning of implants in the posterior mandible: A case report. Clin Oral Implants Res 2001; 12: 539 â 542.; Pinsky HM, Dyda S, Pinsky RW, Misch KA, Sarment DP. Accuracy of threeâ dimensional measurements using coneâ beam CT. Dentomaxillofac Radiol 2006; 35: 410 â 416.; Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A. Accuracy in measurement of distance using limited coneâ beam computerized tomography. Int J Oral Maxillofac Implants 2004; 19: 228 â 231.; Araki K, Maki K, Seki K, et al. Characteristics of a newly developed dentomaxillofacial Xâ ray cone beam CT scanner (CB MercuRay): System configuration and physical properties. Dentomaxillofac Radiol 2004; 33: 51 â 59.; Buser D, Martin W, Belser UC. Optimizing esthetics for implant restorations in the anterior maxilla: Anatomic and surgical considerations. Int J Oral Maxillofac Implants 2004; 19 ( Suppl. ): 43 â 61.

  8. 8
    Academic Journal

    المساهمون: Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, MI.

    وصف الملف: application/pdf

    Relation: Fu, Jia‐hui; Yeh, Chu‐yuan; Chan, Hsun‐liang; Tatarakis, Nikolaos; Leong, Daylene J.M.; Wang, Hom‐lay (2010). "Tissue Biotype and Its Relation to the Underlying Bone Morphology." Journal of Periodontology 81(4): 569-574.; https://hdl.handle.net/2027.42/142069; Journal of Periodontology; Barriviera M, Duarte WR, Januário AL, Faber J, Bezerra AC. A new method to assess and measure palatal masticatory mucosa by coneâ beam computerized tomography. J Clin Periodontol 2009; 36: 564 â 568.; Claffey N, Shanley D. Relationship of gingival thickness and bleeding to loss of probing attachment in shallow sites following nonsurgical periodontal therapy. J Clin Periodontol 1986; 13: 654 â 657.; Huang LH, Neiva RE, Wang HL. Factors affecting the outcomes of coronally advanced flap root coverage procedure. J Periodontol 2005; 76: 1729 â 1734.; Hwang D, Wang HL. Flap thickness as a predictor of root coverage: A systematic review. J Periodontol 2006; 77: 1625 â 1634.; Zigdon H, Machtei EE. The dimensions of keratinized mucosa around implants affect clinical and immunological parameters. Clin Oral Implants Res 2008; 19: 387 â 392.; De Rouck T, Eghbali R, Collys K, De Bruyn H, Cosyn J. The gingival biotype revisited: Transparency of the periodontal probe through the gingival margin as a method to discriminate thin from thick gingiva. J Clin Periodontol 2009; 36: 428 â 433.; Ochsenbein C, Ross S. A reevaluation of osseous surgery. Dent Clin North Am 1969; 13: 87 â 102.; Seibert JL, Lindhe J. Esthetics and periodontal therapy. In: Lindhe J, ed. Textbook of Clinical Periodontology. 2nd ed. Copenhangen, Denmark: Munksgaard; 1989: 477 â 514.; Kan JY, Rungcharassaeng K, Umezu K, Kois JC. Dimensions of periâ implant mucosa: An evaluation of maxillary anterior single implants in humans. J Periodontol 2003; 74: 557 â 562.; Baldi C, Piniâ Prato G, Pagliaro U, et al. Coronally advanced flap procedure for root coverage. Is flap thickness a relevant predictor to achieve root coverage? A 19â case series. J Periodontol 1999; 70: 1077 â 1084.; Evans CD, Chen ST. Esthetic outcomes of immediate implant placements. Clin Oral Implants Res 2008; 19: 73 â 80.; Romeo E, Lops D, Rossi A, Storelli S, Rozza R, Chiapasco M. Surgical and prosthetic management of interproximal region with singleâ implant restorations: 1â year prospective study. J Periodontol 2008; 79: 1048 â 1055.; Greenberg J, Laster L, Listgarten MA. Transgingival probing as a potential estimator of alveolar bone level. J Periodontol 1976; 47: 514 â 517.; Müller HP, Heinecke A, Schaller N, Eger T. Masticatory mucosa in subjects with different periodontal phenotypes. J Clin Periodontol 2000; 27: 621 â 626.; Müller HP, Schaller N, Eger T, Heinecke A. Thickness of masticatory mucosa. J Clin Periodontol 2000; 27: 431 â 436.; Misch KA, Yi ES, Sarment DP. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 2006; 77: 1261 â 1266.; Feldkamp LA, Goldstein SA, Parfitt AM, Jesion G, Kleerekoper M. The direct examination of threeâ dimensional bone architecture in vitro by computed tomography. J Bone Miner Res 1989; 4: 3 â 11.; Kennedy JE. Effect of inflammation on collateral circulation of the gingiva. J Periodontal Res 1974; 9: 147 â 152.; Olsson M, Lindhe J. Periodontal characteristics in individuals with varying form of the upper central incisors. J Clin Periodontol 1991; 18: 78 â 82.; Olsson M, Lindhe J, Marinello CP. On the relationship between crown form and clinical features of the gingiva in adolescents. J Clin Periodontol 1993; 20: 570 â 577.; Eghbali A, De Rouck T, De Bruyn H, Cosyn J. The gingival biotype assessed by experienced and inexperienced clinicians. J Clin Periodontol 2009; 36: 958 â 963.; Smith RG. Gingival recession. Reappraisal of an enigmatic condition and a new index for monitoring. J Clin Periodontol 1997; 24: 201 â 205.

  9. 9
    Academic Journal

    المساهمون: Graduate Periodontics, School of Dentistry, University of Michigan, Ann Arbor, MI., Graduate Periodontics, Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan.

    وصف الملف: application/pdf

    Relation: Chan, Hsun‐liang; Leong, Daylene J.M.; Fu, Jia‐hui; Yeh, Chu‐yuan; Tatarakis, Nikolaos; Wang, Hom‐lay (2010). "The Significance of the Lingual Nerve During Periodontal/Implant Surgery." Journal of Periodontology 81(3): 372-377.; http://hdl.handle.net/2027.42/141105; Journal of Periodontology; Pogrel MA, Thamby S. The etiology of altered sensation in the inferior alveolar, lingual, and mental nerves as a result of dental treatment. J Calif Dent Assoc 1999; 27: 531, 534â 538.; Hillerup S, Stoltze K. Lingual nerve injury in third molar surgery I. Observations on recovery of sensation with spontaneous healing. Int J Oral Maxillofac Surg 2007; 36: 884 â 889.; Gomes AC, Vasconcelos BC, de Oliveira e Silva ED, da Silva LC. Lingual nerve damage after mandibular third molar surgery: A randomized clinical trial. J Oral Maxillofac Surg 2005; 63: 1443 â 1446.; Gülicher D, Gerlach KL. Sensory impairment of the lingual and inferior alveolar nerves following removal of impacted mandibular third molars. Int J Oral Maxillofac Surg 2001; 30: 306 â 312.; Bataineh AB. Sensory nerve impairment following mandibular third molar surgery. J Oral Maxillofac Surg 2001; 59: 1012 â 1017, discussion 17.; Valmasedaâ Castellón E, Beriniâ Aytés L, Gayâ Escoda C. Lingual nerve damage after third lower molar surgical extraction. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000; 90: 567 â 573.; Behnia H, Kheradvar A, Shahrokhi M. An anatomic study of the lingual nerve in the third molar region. J Oral Maxillofac Surg 2000; 58: 649 â 651; discussion 652â 653.; Kiesselbach JE, Chamberlain JG. Clinical and anatomic observations on the relationship of the lingual nerve to the mandibular third molar region. J Oral Maxillofac Surg 1984; 42: 565 â 567.; Greenstein G, Cavallaro J, Tarnow D. Practical application of anatomy for the dental implant surgeon. J Periodontol 2008; 79: 1833 â 1846.; Greenstein G, Cavallaro J, Romanos G, Tarnow D. Clinical recommendations for avoiding and managing surgical complications associated with implant dentistry: A review. J Periodontol 2008; 79: 1317 â 1329.; Karakas P, Uzel M, Koebke J. The relationship of the lingual nerve to the third molar region using radiographic imaging. Br Dent J 2007; 203: 29 â 31.; Hölzle FW, Wolff KD. Anatomic position of the lingual nerve in the mandibular third molar region with special consideration of an atrophied mandibular crest: An anatomical study. Int J Oral Maxillofac Surg 2001; 30: 333 â 338.; Miloro M, Halkias LE, Slone HW, Chakeres DW. Assessment of the lingual nerve in the third molar region using magnetic resonance imaging. J Oral Maxillofac Surg 1997; 55: 134 â 137.; Pogrel MA, Renaut A, Schmidt B, Ammar A. The relationship of the lingual nerve to the mandibular third molar region: An anatomic study. J Oral Maxillofac Surg 1995; 53: 1178 â 1181.; Berberi A, Le Breton G, Mani J, Woimant H, Nasseh I. Lingual paresthesia following surgical placement of implants: Report of a case. Int J Oral Maxillofac Implants 1993; 8: 580 â 582.; Hunt PR. Safety aspects of mandibular lingual surgery. J Periodontol 1976; 47: 224 â 229.; Reinhart TC. Re: Anatomic variation of the position of the lingual nerve. J Periodontol 1990; 61: 305 â 306.; Trost O, Kazemi A, Cheynel N, et al. Spatial relationships between lingual nerve and mandibular ramus: Original study method, clinical and educational applications. Surg Radiol Anat 2009; 31: 447 â 452.; Mozsary PG, Middleton RA. Microsurgical reconstruction of the lingual nerve. J Oral Maxillofac Surg 1984; 42: 415 â 420.; Woelfel JB Sr. Dental Anatomy: Its Relevance to Dentistry, 5 ed. Hagerstown, MD: The Williams & Wilkins Company; 1997.; Olsen J, Papadaki M, Troulis M, Kaban L, O’Neill M, Donoff B. Using ultrasound to visualize the lingual nerve. J Oral Maxillofac Surg 2007; 65: 2295 â 2300.

  10. 10
    Academic Journal

    وصف الملف: application/pdf

    Relation: Peng, Lee‐cheng; Yang, Ching‐chong Jack; Sim, Sang; Weiss, Mitchell; Bielajew, Alex (2007). "Dose comparison of megavoltage coneâ beam and orthogonalâ pair portal images." Journal of Applied Clinical Medical Physics 8(1): 10-20.; http://hdl.handle.net/2027.42/135265; Journal of Applied Clinical Medical Physics; Sillanpaa J, Chang J, Mageras G, et al. Developments in megavoltage cone beam CT with an amorphous silicon EPID: reduction of exposure and synchronization with respiratory gating. Med Phys. 2005; 32 ( 3 ): 819 â 829.; Killoran JH, Kooy HM, Gladstone DJ, Welte FJ, Beard CJ. A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy. Int J Radiat Oncol Biol Phys. 1997; 37 ( 1 ): 213 â 221.; Goitein M, Busse J. Immobilization error: some theoretical considerations. Radiology. 1975; 117 ( 2 ): 407 â 412.; Marks JE, Haus AG, Sutton HG, Griem ML. Localization error in the radiotherapy of Hodgkin’s disease and malignant lymphoma with extended mantle fields. Cancer. 1974; 34 ( 1 ): 83 â 90.; Hunt MA, Schultheiss TE, Desobry GE, Hakki M, Hanks GE. An evaluation of setup uncertainties for patients treated to pelvis sites. Int J Radiat Oncol Biol Phys. 1995; 32 ( 1 ): 227 â 233.; Pasma KL, Kroonwijk M, Quint S, Visser AG, Heijmen BJ. Transit dosimetry with an electronic portal imaging device (EPID) for 115 prostate cancer patients. Int J Radiat Oncol Biol Phys. 1999; 45 ( 5 ): 1297 â 1302.; Herman MG, Kruse JJ, Hagness CR. Guide to clinical use of electronic portal imaging. J Appl Clin Med Phys. 2000; 1 ( 2 ): 38 â 57.; Groh BA, Siewerdsen JH, Drake DG, Wong JW, Jaffray DA. A performance comparison of flatâ panel imagerâ based MV and kV coneâ beam CT. Med Phys. 2002; 29 ( 6 ): 967 â 975.; Yin FF, Guan H, Lu W. A technique for onâ board CT reconstruction using both kilovoltage and megavoltage beam projections for 3D treatment verification. Med Phys. 2005; 32 ( 9 ): 2819 â 2826.; Smitsmans MP, Bois J, Snoke JJ, et al. Automatic prostate localization on coneâ beam CT scans for high precision imageâ guided radiotherapy. Int J Radiat Oncol Biol Phys. 2005; 63 ( 4 ): 975 â 984.; Mosleshâ Shirazi MA, Swindell W, Evans PM. Optimization of scintillation detector in a combined 3D megavoltage CT scanner and portal imager. Med Phys. 1998; 25 ( 10 ): 1880 â 1890.; Moslehâ Shirazi MA, Evans PM, Swindell W, Symondsâ Tayler JR, Webb S, Partridge M. Rapid portal imaging with a highâ efficiency, large fieldâ ofâ view detector. Med Phys. 1998; 25 ( 12 ): 2333 â 2346.; Ford EC, Chang J, Sidhu K, et al. Coneâ beam CT with megavoltage beams and an amorphous silicon electronic portalâ imaging device: potential for verification of radiotherapy of lung cancer. Med Phys. 2002; 29 ( 12 ): 2913 â 2924.; Pouliot J, Baniâ Hashemi A, Chen J, et al. Lowâ dose megavoltage coneâ beam CT for radiation therapy. Int J Radiat Oncol Biol Phys. 2005; 61 ( 2 ): 552 â 560.; Simpson RG, Chen CT, Grubbs EA, Swindell W. A 4â MV CT scanner for radiation therapy: the prototype system. Med Phys. 1982; 9 ( 4 ): 574 â 579.; Seppi EJ, Munro P, Johnsen SW, et al. Megavoltage coneâ beam computed tomography using a highâ efficiency image receptor. Int J Radiat Oncol Biol Phys. 2003; 55 ( 3 ): 793 â 803.; Wong JW, Slessinger ED, Hermes RE, Offutt CJ, Roy T, Vannier MW. Portal dose images. I: Quantitative treatment plan verification. Int J Radiat Oncol Biol Phys. 1990; 18 ( 6 ): 1455 â 1463.; Kudchadker RJ, Chang EL, Bryan F, Maor MH, Famiglietti R. An evaluation of radiation exposure from portal films taken during definitive course of pediatric radiotherapy. Int J Radiat Oncol Biol Phys. 2004; 59 ( 4 ): 1229 â 1235.; Ying X, Geer LY, Wong JW. Portal dose images. II: Patient dose estimation. Int J Radiat Oncol Biol Phys. 1990; 18 ( 6 ): 1465 â 1475.; Morin O, Gillis A, Chen J, et al. Megavoltage coneâ beam CT: system description and clinical application. Med Dosim. 2006; 31 ( 1 ): 51 â 61.